background image

 

 

 

   

Information on property damage or 

malfunctions 

Typographic features of warning 

notes 

 

Malfunctions will occur if the equipment is 
installed in a wrong position or with the flow 
pattern in the opposite direction of the fluid flow. 
This may result in damage to the equipment or 
the installation. Make sure that the flow pattern 
indicated in this installation and operating 
manual matches the direction of the fluid flow in 
the pipe. 

 

DANGER 

Notes with the heading DANGER warn 
against imminent dangerous situations that 
can lead to death or serious injuries. 

  

 

CAUTION 

Notes with the heading CAUTION warn 
against dangerous situations that could 
lead to minor or moderate injuries. 

 

If the material is unsuitable for the fluid, 
increased wear may occur and fluid may 
escape. Make sure that the material is suitable 
for the fluid used in your installation. 

Qualification of personnel 

  

Formatting features for warnings 

of property damage 

A qualified person must be acquainted with and 
experienced in the following: 

 

the pertinent on-site rules and regulations for 
preventing fire and explosions 

 

Attention! 

This information warns of a situation 
leading to property damage. 

 

working on pressure equipment 

 

making pipe connections 

 

working with dangerous (hot or pressurized) 
fluids 

  

Description 

 

lifting and transporting loads 

 

observing all notes and instructions in this 
installation & operating manual and the 
applicable documents 

Scope of supply and equipment 

specification 

  

Protective gear 

Scope of supply 

The required protective gear depends on the types 
of fluid used and the regulations on site. For more 
information on suitable safety clothing and safety 
gear refer to the safety data sheet of the fluid in 
question. 

Our equipment is delivered packed and ready for 
assembly. 

  

Equipment specification 

  

The equipment features the following connections: 

Protective gear comprises the following items: 

 

Connection for steam or air inlet 

 

protective helmet 

 

Connection for steam or air outlet 

 

work boots 

 

Connection for condensate outlet 

 

industrial leather gloves 

 

Vent (nominal size 200 upwards) 

  

  

Summary of Contents for TD

Page 1: ...Steam Drier Steam Purifier TD Air Drier Air Purifier TP Original Installation Instructions 819479 02 ...

Page 2: ...tives 8 Storing and transporting the equipment 8 Storing the equipment 8 Transporting the equipment 8 Mounting and connecting the equipment 9 Preparing installation 9 Connecting the equipment 10 Operation 11 After operation 12 Removing external dirt deposits 12 Maintaining the equipment 12 Installing spare parts 12 Putting the equipment out of operation 12 Removing harmful substances 12 Removing t...

Page 3: ...pment Please note that in addition to the instructions given in this installation operating manual you must also observe all locally applicable rules and regulations concerning the prevention of accidents as well as approved safety guidelines for good professional practice Safety Use for the intended purpose The TD steam drier steam purifier is installed in steam systems The equipment is used to s...

Page 4: ...sed or unintended activation Make sure that all locally applicable regulations on safety and the prevention of accidents are strictly adhered to The pipes and the equipment must have cooled down to room temperature approx 20 C Risk of minor injuries If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment Before ...

Page 5: ...lified person must be acquainted with and experienced in the following the pertinent on site rules and regulations for preventing fire and explosions Attention This information warns of a situation leading to property damage working on pressure equipment making pipe connections working with dangerous hot or pressurized fluids Description lifting and transporting loads observing all notes and instr...

Page 6: ...ction for steam or air outlet 4 Name plate 6 Connection for condensate outlet No Designation 1 Connection for steam or air inlet 2 Connection for steam or air outlet 3 Vent only needed for work by the manufacturer 4 Name plate 5 Inspection hole 6 Connection for condensate outlet 7 Lugs nominal size 200 upwards ...

Page 7: ...team or air Manufacturer Type designation Min service temperature Max service temperature Max service pressure Direction of flow Mark e g CE UKCA if required Year of construction Serial number Type of vessel Weight Body of regulations Test pressure Test date Volume Task and function Purpose The TD steam drier steam purifier is installed in steam systems The equipment is used to separate water susp...

Page 8: ...tatic charging is the responsibility of the manufacturer or operator of the system Indoor air clean salt free and non corrosive Temperature 5 40 C Make sure that all these requirements are always met when storing the equipment Storing and transporting the equipment Please contact the manufacturer if you cannot comply with the recommended storage conditions Transporting the equipment Attention Equi...

Page 9: ...hot or hazardous fluid is in the equipment or the pipes Make sure that the pipes upstream and downstream of the equipment are depressurised Make sure that the installation is switched off and protected against unauthorised or unintended activation Make sure that the equipment and the pipes have cooled down to room temperatures Wear protective clothing that is suitable for the fluid and if necessar...

Page 10: ...ue to damaged seals can harm the environment Make sure that sealing surfaces are undamaged Clean sealing surfaces before installing a new seal Replace every seal after disassembly Tighten threaded joints to the specified torque Make sure that the equipment is not under any stress when installed Equipment nominal size 200 and upwards is fitted with lugs 7 for support However these lugs are not pre ...

Page 11: ...sure that the equipment is safely mounted and that all connections are made correctly Operation When warm check the flanged unions for tightness Do not work on the equipment while it is operating Re tighten the bolted connections if necessary During operation the surface of the equipment gets hot This presents the risk of burns Lag the surface of the equipment with suitable insulating material ...

Page 12: ...harmful substances DANGER If the equipment is used in contaminated areas there is a risk of severe injuries or death caused by harmful substances in or on the equipment Only qualified personnel are allowed to perform work on contaminated equipment Always wear the protective clothing prescribed for contaminated areas when working on the equipment Make sure that the equipment is completely decontami...

Page 13: ...ten the lugs from the supports Place the equipment on a suitable surface Remove all residues from the equipment Store the equipment as described on page 8 For the disposal of all residues observe the pertinent legal regulations concerning waste disposal Re using equipment after storage Observe the following instructions if you want to remove the equipment and use it again somewhere else Removing t...

Page 14: ...eft to right PN Material Flange Pipe Base 16 1 0460 P250GH 1 0345 P235GH N 1 0425 P265GH 16 1 4571 X6CrNiMoTi17 12 2 40 1 0460 P250GH 1 0345 P235GH N 1 0425 P265GH You can return the equipment to your contractual partner Make sure that all harmful substances are removed from the equipment Pay attention to the instructions in section Transporting the equipment from page 8 Pack the equipment in its ...

Page 15: ...500 230 740 49 0 175 125 150 25 320 560 240 870 76 0 200 150 200 25 150 350 650 285 1 055 119 0 250 150 200 250 25 150 400 720 330 1 170 178 0 Manufacturer s declaration You can find details on the conformity of the equipment in our Declaration of Conformity or Manufacturer s Declaration GESTRA AG Münchener Straße 77 28215 Bremen Germany You can download the latest Declaration of Conformity or Man...

Page 16: ...world www gestra de GESTRA AG Münchener Strasse 77 28215 Bremen Germany Phone 49 421 3503 0 Fax 49 421 3503 393 e mail info de gestra com Web www gestra com 819479 02 05 2021 kx_mm 808935 03 GESTRA AG Bremen Printed in Germany ...