Troubleshooting
Problem
Cause
Remedy
The flow rate is too low.
The blow-off valve
is open.
Close the blow-off valve.
The equipment is losing
steam.
The blow-off valve
is open.
Close the blow-off valve.
Fluid escapes
(equipment is leaking).
The connections
are not tight.
Provide the connections with
leakproof seals.
Medium is escaping
(leakage).
The blow-off valve
is leaking.
Replace the blow-off valve.
The flow rate is too low.
The equipment is cold or
only lukewarm.
The strainer is
clogged.
Open the blow-off valve and leave
it open until the strainer is clean.
You can find further information on problems and malfunctions in the valve Installation
& Operating Manual.
➢
If faults occur that are not listed above or cannot be corrected, please contact our
Technical Service or authorized agency in your country.
EN