9
4
3.
Operating Procedure with Standard Controller
With your rotary handpiece fitted with a selected tool, connect the Gesswein
Power Controller to an electrical supply and the handpiece to one of the two
output sockets provided.
Set the Slide Rheostat on the Controller to “Low” or the “0” position. Put the
Controller Main Switch to the “ON” position, which lights up a pilot light that indi-
cates your rotary handpiece is ready to use.
To increase the speed of the rotary handpiece, move the Slide Rheostat toward
“High” or “10.” You can then begin working. When work is completed, put the
Main Switch to “OFF.”
To operate your rotary handpiece using the optional Variable-Speed Foot
Rheostat or optional On/Off Foot Switch, please refer to the Power Hand 2X
Controller Instruction Manual for proper connection. The handpiece will not
rotate until the foot rheostat/switch is depressed. The rheostat provides infinitely
variable speed control; the switch only turns handpiece on and off (operates at
speed selected on control unit).