33
IMPIANTO IDRAULICO - PLUMBING SySTEM - INSTALLATION HyDRAULIqUE - HyDRAULISCHE ANLAGE -
INSTALACIóN HIDRáuLICA - ГИДРАВЛИчЕСКАЯ СИСТЕМА - ΥΔΡΑΥΛΙΚΟ ΣΥΣΤΗΜΑ -
水力设备
ING
Technical data for the plumbing system:
- Minimum working pressure: 2 bar
- Working pressure: recommended operating field 3 ÷ 4 bar
- Maximum working pressure: 5 bar (Install a pressure reducer for higher hydraulic pressures)
- Maximum working temperature: 65°c
- Floor waste required with capacity ≥ 60 l/min.
- 18,2 kg empty weight of the complete head shower (with water about 20,7 kg)
Data for plant dimensioning
Feeding pipes for the shower system [A1 - A2 - A3]: minimum internal diameter 12 mm
Static
pressure
[ bar ]
Minimum required feeding
for a correct working of the shower system
( 1 )
Rain Function [A1]
[ l/min ]
( 2 )
Cascade Function [A2]
[ l/min ]
( 3 )
Water Spray Function [A3]
[ l/min ]
2
26
17
It is not
binding
3
21
16
4
19
15
5
18,5
14
( 1 ) Minimum delivery from head shower for the correct working “Rain”: 16 l/min [ B1 ].
( 2 ) Minimum delivery from head shower for the correct working “Cascade”: 11 l/min [ B2 ].
( 3 ) Minimum pressure for the correct working “Water spray”: > 2 bar.
Data for boiler and waste dimensioning
Static
pressure
[ bar ]
Maximum delivery for the shower system
fed with internal 12 mm Ø pipes
Rain Function [B1]
[ l/min ]
Cascade Function* [B2]
[ l/min ]
Water Spray Function [B3]
[ l/min ]
2
19 [ with limiter ]
16
1,6
3
19 [ with limiter ]
16 [ with limiter ]
1,9
4
19 [ with limiter ]
16 [ with limiter ]
2,1
5
19 [ with limiter ]
16 [ with limiter ]
2,4
(*) For the correct working of the cascade, with working pressures ≥ 3 bar always install a flow limiter (16
l/min).
Summary of Contents for 32855
Page 46: ...46 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 5...
Page 51: ...51 INSTALLAZIONE INSTALLATION INSTALLATION INSTALLATION INSTALACI N Fig 84 mm 4 mm 4 mm 4 mm...
Page 58: ...58 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N...
Page 61: ...61 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N Fig 16 Fig 17 Fig 18...
Page 69: ...69 MANUTENZIONE MAINTENANCE ENTRETIEN WARTUNG MANUTENCI N CN...