31
GB
5.5
Environmental protection
If batteries need to be replaced, please observe the following:
•
Take used GESIPA
®
batteries back to your agent or to GESIPA
®
for recycling.
•
Never throw discarded batteries into the waste, into fire or into water!
6. Troubleshooting
6.1
Blind rivet nut does not screw on
Cause
Corrective measures
Nut thread defective
Use new nut
Threaded mandrel defective
Change threaded mandrel (Point 3.1)
Nut does not rest against nosepiece
Threaded mandrel length x incorrect; adapt to nut
length (see point 3.2)
Nut unscrew again
Keep switch 9 pressed until the tool stops (Point
4.1)
No battery
Error indicator on the display E4
Charge battery (Point 5.3)
6.2
Nut is not screwed off
Cause
Corrective measures
Nut thread deformed/destroyed due to excessive
setting force
Error indicator on the display E3
Reduce setting force (Section 3.3); remove using
hexagon screwdriver (Section 4.2; see Fig. 5)
6.3
Set blind rivet nut is loose
Cause
Corrective measures
Setting force too low
Define setting force correctly (Section 3.3)
Switch released before the defined setting force
is reached.
Riveting is faulty!
Error indicator on the display: E1
Execute setting sequence correctly (Section 4.3)