background image

78

© GES Electronic & Service GmbH     www.ges-electronic.de 

 Series

MC

S

 Series

Part as delivered

cap (1), clamping rubber (2), outer cone (3), inner 
cone (4), contacts (5), insulation part (6), housing (7)

Place inner cone (4) on cable

Place cap (1), clamping rubber (2) and outer 

cone (3) on cable

     Respect correct order of parts (see picture).

Remove dielectric insulation of single wires  

(L2 = 4 mm [.157"])

      Do not damage conductor.

Carefully remove cable jacket  

(L1 = 28 mm [1.102"])

       Do not damage metal shield. 

 Do not damage dielectric insulation.

Crimp or solder one contact (5) each on every conductor

      Tin-solder must not remain on contact surface!

Fold back shield braid over jacket

Completely widen shield braid. Push outer cone (3) 

and clamping rubber (2) under shield braid against 

inner cone (4) until shield braid clamps between outer 

cone (3) and inner cone (4)

Remove any filling elements from cable

Cut overlapping shield braid

       Carefully remove loose shield parts. Loose shield 

parts can cause electrical break down.

1.

6.

2.

7.

3.

8.

4.

9.

5.

10.

!

!

!

!

!

Assembly instructions (KB/KS)