Gerni NEPTUNE 2 Operating Instructions Manual Download Page 5

5

1)

 Options / model variants

NEPTUNE 2

If the mains power lead is dam-
aged, to avoid hazards, this 
must be replaced either by the 
manufacturer or through his 
customer service or a similarly 
qualified person.

CAUTION!

Unsuitable extension leads can 
represent a source of danger. 
Always unwind lead from the 
reels completely to prevent the 
mains power lead overheating.

Connectors and couplings of 
power supply cords and exten-
sion leads must be watertight.

When using an extension lead, 
check the minimum cross-sec-
tions of the cable:

Cable length
m

Cross section

<16 A

<25 A

up to 20 m

ø1.5mm² ø2.5mm²

20 to 50 m

ø2.5mm² ø4.0mm²

Check the rated voltage of the 
high-pressure cleaner before 
connecting it to the mains power 
supply. Ensure that the voltage 
shown on the rating plate cor-
responds to the voltage of the 
local mains power supply.

It is important that the electrical 
connection for this appliance 
has been installed by an electri-
cian and in compliance with IEC 
60364 and the country-specific 
regulations.

We recommend that the electri-
cal connection to this appliance 
should incorporate 
–  either a fault current circuit 

breaker, which cuts off the 
mains voltage if the fault 
current exceeds 30 mA for 
30 ms,

–  or an earth resistance meter.

Check that cleaning will not 
result in dangerous substanc-
es (e.g. asbestos, oil) being 
washed off the object to be 
cleaned and harming the envi-
ronment.

Do not clean delicate parts 
made of rubber, fabric, etc. with 
the 0° jet.  Keep some distance 
between high pressure nozzle 
and surface in order to prevent 
the surface from damage.

Do not use the high-pressure 
hose for lifting loads.

The maximum permissible 
working pressure and tempera-
ture are printed on the high-
pressure hose.

 

Store the cleaner 
where it will not be ex-
posed to frost or use 

anti-freeze liquid!

Never operate the cleaner with-
out water. Even brief shortages 
of water result in severe dam-
age to the pump seals.

Operation

Keep cabinet closed during op-
eration.

Do not damage the mains pow-
er lead (e.g. by driving over it, 
pulling or crushing it).

Disconnect the power cord by 
pulling the plug only (do not pull 
or tug the power cord).

IMPORTANT!

This appliance has been de-
vised for use with cleansing 
agents that are supplied and 
recommended by the manufac-
turer. The use of other cleansing 
agents or chemicals can impair 
the safety of the appliance.

CAUTION!

The appliance is intended to 
be used with heating oil EL or 
diesel oil.

 

Unsuitable fuels (e.g. 

petrol) must not be used as they 
can represent a source of dan-
ger.

If the machine is to be oper-
ated at fuel stations or in other 
potentially hazardous areas, 
the machine may only be em-

ployed outside the hazard areas 
defined in the German  „Techni-
cal Guidelines for Inflammable 
Fluids“ applicable at the point 
of use due to the potential ex-
plosion hazard posed by the 
burner.

When setting up the appliance 
indoors, always ensure suitable 
ventilation and that the exhaust 
gases are expelled in a suitable 
way. We will be glad to provide 
tips for connection systems, on 
request.

If the machine is to be con-
nected to a flue gas stack, then 
local building regulations must 
be observed. We will be glad to 
provide tips for connection sys-
tems, on request.

CAUTION!

Beware of hot water and 
steam discharge up to 
150°C when operating in 
steam stage.

CAUTION!

Do not touch or cover 
the exhaust. Risk of 
burns and fire.

Do not touch, cover or place hose 
or cord over the chimney. Danger 
for persons, risk of overheating 
and fire.

Electrical equipment

CAUTION!

Never spray electrical equip-
ment with water: danger for per-
sons, risk of short-circuiting.

Switching on the cleaner may 
cause voltage 

fl

 uctuations.

Voltage fluctuations should not 
occur if the impedance at the 
transfer point is less than 0.15



If in doubt ask your local elec-
tricity supplier.

Maintenance and repair
CAUTION!

Always remove the plug from 
the mains plug socket before 

Summary of Contents for NEPTUNE 2

Page 1: ...isning S Operating guide UK Betribsanleitung D Mode d emploi F Gebruiksaanwijzingen NL Instrucciones de manejo E Instru es para uso P K ytt opas FI Instrukcja obs ugi PL GR 06951019 01 107145345 C Ope...

Page 2: ...0 F 210 80 85 300 C 175 105 120 60140 70160 90 195 0 100 0 30 40 50 2 1 3 4 0 300 CUTOUT 1 F 210 80 85 C 175 105 120 60140 701 60 90 195 100 30 40 50 0 2 1 3 4 5 7 11 9 2 10 19 20 18 6 3 1 4 8 12 13 1...

Page 3: ...necting the water supply 8 3 7 Electrical connection 9 3 8 Antifreeze before first use 9 4 1 Switching on the cleaner 10 4 2 Connections 10 4 3 Pressure regulation Ergo Vario Press Gun 1 11 4 4 Using...

Page 4: ...nstruc tions and the binding accident prevention regulations valid in the country of use observe rec ognised regulations for safety and proper use Do not use any unsafe work techniques Do not tie the...

Page 5: ...r Even brief shortages of water result in severe dam age to the pump seals Operation Keep cabinet closed during op eration Do not damage the mains pow er lead e g by driving over it pulling or crushin...

Page 6: ...ised inspectors The complete Accident Preven tion Regulations for Working with Liquid Spray Jet Devices are available from the Carl Hey manns Verlag KG Luxemburger Strasse 449 50939 Cologne or from th...

Page 7: ...the burner may be necessary to take account of altitude and the resulting air pressure This is true whether your fuel is Ker osene or Diesel Your Gerni hot water pressure washer was thoroughly tested...

Page 8: ...h pressure cleaner diesel tank 1 month Diesel stored externally for more than 6 months is not al lowed to be filled into Nilfisk ALTO high pressure cleaners Diesel EN 590 is not recom mended for use i...

Page 9: ...troyed CAUTION When using cable reels 1 Due to the risk of overheat ing and fire always unwind the power supply cord fully The cleaner may only be con nected to a correctly installed electrical instal...

Page 10: ...it by turning it to the left 2 Insert the nipple of the spray lance E into the quick re lease connection and turn the quick release grip to the right D 3 Pull the spray lance or other accessory forwar...

Page 11: ...l data 4 3 Pressure regulation Ergo Vario Press Gun 1 1 Operate the Vario trigger in order to vary the water flow and thereby the pressure 2 Push the trigger forwards to obtain full pressure and flow...

Page 12: ...to break down tough layers of dirt additional mechanical effect may be required Special lances and rotary or wash brushes offer this supplementary effect that cuts through dirt 5 1 5 High Water Flow o...

Page 13: ...ents Intensive J25 Multi Combi Active Alkafoam Disinfectant DES 3000 1 Apply thick foam over the surfaces to be cleaned Apply on dry surfaces Apply from top to bottom on vertical surfaces Let the foam...

Page 14: ...protected against frost when antifreeze solution emerges from the spray gun 9 Lock the safety catch on the spray gun 10 Close the cover 11 Switch off the cleaner 12 To avoid any risks store the cleane...

Page 15: ...r and clean it 3 Remount the filter and quick coupling 7 2 2 Maintenance of fuel filter 1 Open hose clips 2 Replace fuel filter 3 Close hose clips 4 Dispose the cleaning solu tion damaged filter in ac...

Page 16: ...ant light Low fuel level Top up fuel Cold water operation is pos sible Flashing light Low AntiStone level Top up AntiStone Constant light Service interval has expired Flashing light Service interval d...

Page 17: ...d the machine is running normally again No detergent drawn in Detergent tank empty Top up detergent tank Dirt in detergent tank Clean detergent tank Suction valve at cleaning agent inlet soiled Remove...

Page 18: ...validated if the machine is not serviced as de scribed 9 3 Technical data 9 Further information 9 1 Recycling the cleaner If the cleaner is discarded make it unusable immediately 1 Unplug the cleaner...

Page 19: ...ISO 12100 1 EN ISO 12100 2 EN 60335 2 79 EN 55014 1 2002 EN 55014 2 2001 EN 61000 3 2 2006 Applied national standards and technical specifications IEC 60335 2 79 Name and address of the person author...

Page 20: ...AUSTRALIA Nilfisk Advance Pty LTd Unit 1 13 Bessemer Street Blacktown NSW 2148 Phone 1300 556 710 E mail sales gerni com au...