background image

P. 5

 重要說明

 為安全起見,初次使用產品前請先細 
 閱本說明書,並保存說明書,以便作 
 參考之用。

 本產品只供家居使用。請必須依照本 
 說明書內的指示安裝及操作。

˙ 

若同時使用抽油煙機及燃氣爐具, 

   廚房應保持良好通風及避免對流的
   情況。安裝抽油煙機機體時應保持 
   水平。

˙ 

應使用風口略低的安裝風管,以防 

   油污回流。且至機體的距離宜短,  
   轉彎宜少(一般一個),以便迅速 
   排煙。

˙ 

抽油煙機不應與使用煤氣或其他燃氣 

   的爐具共用同一排氣煙道。

˙ 

電源供應必須符合產品要求之電 

   壓,三腳電源必須有可靠的地線。

˙ 

更換燈管時應先切斷電源,燈管功 

   率須按燈罩所示。

˙ 

使用過程中,凡出現異常噪音、風 

   輪不轉、氣味、煙霧等,應切斷電 
   源檢查修理。若是電器故障,切勿 
   擅自拆裝,並須由維修部或持牌技 
   術人員修理。

注意事項 

NOTICE BEFORE USE

IMPORTANT

For safety purpose you should read the 

instructions carefully before using the appliance 

for the first time. Save the instructions for future 

reference.

The appliance is designed for domestic use 

and may only be installed and operated in 

accordance with these instructions for use.

˙ 

Keep good ventilation in the kitchen without  

  causing convection, while operating  

 

  range hood and stove at the same time.  

  Make sure the range hood is horizontally  

  balanced when installing. 

˙ 

Use exhaust pipe with a lowly positioned vent  

  to prevent grease residual from backflowing.  

  Its distance from the range hood should be  

  short, and there should be as little bending  

  as possible (one bend in general) to facilitate  

  discharge of fumes. 

˙

The vapour exhausted from the rangehood  

  must not be discharged to the same piping  

  used for discharging gas or other fuels. 

˙

Use power supply with the product’s    

  required voltage. Three-core power socket  

  should have a reliable ground connection. 

˙

Disconnect the power supply before changing  

  the lamps. Lamps with the rated power  

  stated on the lampshade must be used. 

˙

Disconnect the power supply immediately  

  if turbine impeller does not run, abnormal 

  noise, odour or smoke appears. If the   

  appliance is out of order, do not dismantle  

  it yourself. Contact our Customer Service  

  Department or licensed technicians to repair.  

Summary of Contents for DWL-509A

Page 1: ...DWL 509A M 08 1 DWL 509A Air Curtain Range Hood...

Page 2: ...and the original purchase invoice will be required for any repairs Warranty will be invalid if information provided is found to be inaccurate or purchase invoice is not presented Model No DWL 509A Se...

Page 3: ...d mail it back to us along with a photocopy of the purchase invoice Warranty Card and invoice copy will not be returned IMPORTANT NOTICE Room 2 4 Upper G F Newport Centre 116 Ma Tau Kok Road Tokwawan...

Page 4: ...ICE BEFORE USE 5 PRODUCT FEATURES 7 PRODUCT STRUCTURE 8 CONTROL BUTTONS 9 INSTALLATION INSTRUCTIONS 11 ELECTRICAL SCHEMATICS 13 CARE MAINTENANCE 14 TROUBLESHOOTING 16 TECHNICAL SPECIFICATIONS 17 WARRA...

Page 5: ...backflowing Its distance from the range hood should be short and there should be as little bending as possible one bend in general to facilitate discharge of fumes The vapour exhausted from the range...

Page 6: ...Do not turn on the stove and the range hood when not cooking must not allow the gas fire to heat up the range hood directly The grease in the oil collector is harmful to human body so it must not be...

Page 7: ...t greasy vapour from a low position preventing users from absorbing harmful substances from the fumes Ultra thin wall mount design neither blocking the sight nor knocking the head Horizontal placement...

Page 8: ...pe Cover 2 Control Panel 3 Cover Panel Left and Right 4 Smoke Collecting Cover 5 Grease Filter 6 Grease Outlet 7 Rubber Padding 8 Air Outlet 9 Exhaust Pipe 10 Electrical Circuit Box 11 Power Plug 12 M...

Page 9: ...for 3 seconds to shutdownallfunctions includingfan display screen lighting aircurtainandtimer If no button action is detected display screen automatically dims down after 10 minutes Note Unit will aut...

Page 10: ...itch on Air Curtain function 5 TIMER Press once short to set Timer Hold down 5 seconds to set Clock Time Set Timer During operation press this button once and a timer symbol will appear on display scr...

Page 11: ...re the hood 2 During installation remove the Exhaust Pipe Cover After finishing the installation of the hood install the Exhaust Pipe Cover If there is problem installing the left and right cover pane...

Page 12: ...etachment Then use the special loops to secure them onto the exterior ring of the Air Outlet 4 According to different interior settings either install Exhaust Pipes to discharge to the outside or conn...

Page 13: ...llow Green Brown Green Black Red Blue Red Green L L N N 10W 10W 4 5uf 6 Fig 6 5 Fig 5 Dimensions Diagram White White White Black Black Brown INSTALLATION INSTRUCTIONS Centre of Mounting Hook On Off Sw...

Page 14: ...he function of separating grease and fume is good the speed of oil accumulation is high It is advisable to dischargethegreaseonceevery 4months Method remove the grease filter place the oil collector u...

Page 15: ...rior grease filters by reversing the operation place the grease filter panel into the upper inlay trough push further inside and insert downwards 5 Wash the charcoal filter of the air inlet of the air...

Page 16: ...or damaged Motor is damaged Get impeller back to normal Repair or replace Repair or replace 3 The hood vibrates Not firmly mounted Not installed securely Impeller is damaged and becomes imbalanced Se...

Page 17: ...without prior notice Phenomenon Possible Cause Solution 5 Fan works at one speed but not at another Power switch malfunction Circuit not connected well Repair or replace Repair or replace 6 Does not...

Page 18: ...P 18 WARRANTY TERMS CONDITIONS 1 2 3 4 5 6...

Page 19: ...others casing of hood body light bulbs filters plastic parts and accessories such as oil collecting cups operating failures resulted by incorrect voltage improper operations and unauthorized installa...

Page 20: ...x E mail German Pool Hong Kong Limited Room 2 4 Upper Ground Floor New por t Centre 116 Ma Tau Kok Road Tokwawan Kowloon Hong Kong All rights reserved Copying reproducing or using the contents of this...