background image

P. 19

保用條款 

WARRANTY TERMS & CONDITIONS

保用條款 

WARRANTY TERMS & CONDITIONS

  Under normal operations, the range hood will receive a 1-year full warranty provided by 

  German Pool (effective starting from the date of purchase).

 

1.  Warranty Card or Online Warranty Registration Form must be completed and    

 

  returned to German Pool within 10 days of purchase. Warranty will become  

 

 

  effective immediately after the receipt of registration. No confirmation notice will  

 

  be sent to Customer.

2.   Customer who fails to present original purchase invoice will be disqualified for free warranty.

3.  Customer should always follow the operating instructions. This warranty does not  

 

  apply to:

  -   labour costs for installation, on-site check-up, replacement of parts and other  

 

    transportation costs;

  -   damages caused by accidents of any kind (including transport and others); 

  -   casing of hood body, light bulbs, filters, plastic parts and accessories such as oil  

 

    collecting cups;

  -   operating failures resulted by incorrect voltage, improper operations and    

 

    unauthorized installations or repairs.

.  This warranty is invalid if:

  -   purchase invoice is modified by unauthorized party;

  -   product is used for any commercial or industrial applications;

  -   product is repaired or modified by unauthorized personnel, or unauthorized   

 

    parts are installed;

  -   serial number is modified, damaged or removed from the product.

5.  German Pool will, in its discretion, repair or replace any defective part. 

.  This warranty will be void if there is any transfer of ownership from the original purchaser.

   * Service area includes Hong Kong Island, Kowloon and New Territories only.  

 

 

  Repairs in Tung Chung, Discovery Bay or other areas are subject to an extra  

 

 

  service charge.

If there is any inconsistency or ambiguity between the English version 

and the Chinese version, the Chinese version shall prevail.

 

Summary of Contents for DWL-509A

Page 1: ...DWL 509A M 08 1 DWL 509A Air Curtain Range Hood...

Page 2: ...and the original purchase invoice will be required for any repairs Warranty will be invalid if information provided is found to be inaccurate or purchase invoice is not presented Model No DWL 509A Se...

Page 3: ...d mail it back to us along with a photocopy of the purchase invoice Warranty Card and invoice copy will not be returned IMPORTANT NOTICE Room 2 4 Upper G F Newport Centre 116 Ma Tau Kok Road Tokwawan...

Page 4: ...ICE BEFORE USE 5 PRODUCT FEATURES 7 PRODUCT STRUCTURE 8 CONTROL BUTTONS 9 INSTALLATION INSTRUCTIONS 11 ELECTRICAL SCHEMATICS 13 CARE MAINTENANCE 14 TROUBLESHOOTING 16 TECHNICAL SPECIFICATIONS 17 WARRA...

Page 5: ...backflowing Its distance from the range hood should be short and there should be as little bending as possible one bend in general to facilitate discharge of fumes The vapour exhausted from the range...

Page 6: ...Do not turn on the stove and the range hood when not cooking must not allow the gas fire to heat up the range hood directly The grease in the oil collector is harmful to human body so it must not be...

Page 7: ...t greasy vapour from a low position preventing users from absorbing harmful substances from the fumes Ultra thin wall mount design neither blocking the sight nor knocking the head Horizontal placement...

Page 8: ...pe Cover 2 Control Panel 3 Cover Panel Left and Right 4 Smoke Collecting Cover 5 Grease Filter 6 Grease Outlet 7 Rubber Padding 8 Air Outlet 9 Exhaust Pipe 10 Electrical Circuit Box 11 Power Plug 12 M...

Page 9: ...for 3 seconds to shutdownallfunctions includingfan display screen lighting aircurtainandtimer If no button action is detected display screen automatically dims down after 10 minutes Note Unit will aut...

Page 10: ...itch on Air Curtain function 5 TIMER Press once short to set Timer Hold down 5 seconds to set Clock Time Set Timer During operation press this button once and a timer symbol will appear on display scr...

Page 11: ...re the hood 2 During installation remove the Exhaust Pipe Cover After finishing the installation of the hood install the Exhaust Pipe Cover If there is problem installing the left and right cover pane...

Page 12: ...etachment Then use the special loops to secure them onto the exterior ring of the Air Outlet 4 According to different interior settings either install Exhaust Pipes to discharge to the outside or conn...

Page 13: ...llow Green Brown Green Black Red Blue Red Green L L N N 10W 10W 4 5uf 6 Fig 6 5 Fig 5 Dimensions Diagram White White White Black Black Brown INSTALLATION INSTRUCTIONS Centre of Mounting Hook On Off Sw...

Page 14: ...he function of separating grease and fume is good the speed of oil accumulation is high It is advisable to dischargethegreaseonceevery 4months Method remove the grease filter place the oil collector u...

Page 15: ...rior grease filters by reversing the operation place the grease filter panel into the upper inlay trough push further inside and insert downwards 5 Wash the charcoal filter of the air inlet of the air...

Page 16: ...or damaged Motor is damaged Get impeller back to normal Repair or replace Repair or replace 3 The hood vibrates Not firmly mounted Not installed securely Impeller is damaged and becomes imbalanced Se...

Page 17: ...without prior notice Phenomenon Possible Cause Solution 5 Fan works at one speed but not at another Power switch malfunction Circuit not connected well Repair or replace Repair or replace 6 Does not...

Page 18: ...P 18 WARRANTY TERMS CONDITIONS 1 2 3 4 5 6...

Page 19: ...others casing of hood body light bulbs filters plastic parts and accessories such as oil collecting cups operating failures resulted by incorrect voltage improper operations and unauthorized installa...

Page 20: ...x E mail German Pool Hong Kong Limited Room 2 4 Upper Ground Floor New por t Centre 116 Ma Tau Kok Road Tokwawan Kowloon Hong Kong All rights reserved Copying reproducing or using the contents of this...

Reviews: