German pool crx9 Operating Instructions Manual Download Page 38

CRX 9

請填妥以下空格並與發票一併保存,以便維修時核對資料。用戶提供本公司之所有資料必須正確無誤,否則免費保用將會無效。

請填妥以下空格並與發票一併保存,以便維修時核對資料。用戶提供本公司之所有資料必須正確無誤,否則免費保用將會無效。

Please fill out the form below. This information and the purchase invoice will be required for any repairs. Warranty will be invalid 

if information provided is found to be inaccurate. 

型號 

型號 

Model No. :

CRX9

機身號碼 

Serial No. : 

機身號碼 

購買商號 

Purchased From : 

購買商號 

發票號碼 

Invoice No. :  

發票號碼 

購買日期 

購買日期 

Purchase Date :  

保用條例

保用条例

Warranty Terms & 

Conditions

此保用提供德國寶產品之機件在正常使
用下壹年保用(自購買日起計算)。

貴戶須在購機十天內,以下列其中一種
方式向本公司登記資料,保用手續方正
式生效﹕

1) 填妥本公司網頁內之保用登記表格      

www.germanpool.com/warranty

2) 填妥保用登記卡,並連同購機發票之

副本一併郵寄到客戶服務總部 (本公
司將不發還發票副本或登記卡)。 

1. 未能出示購買發票正本者,將不獲免

費維修服務。

2.  用戶應依照說明書的指示操作。本保

用並不包括﹕

    - 任何附件及輔助裝置﹔
    - 因天然與人為意外造成的損壞 
      (包括運輸及其它)﹔
    - 電源接合不當、不依說明書而錯誤 
      或疏忽使用本機所引致之損壞。

3.  於下列情況下,用戶之保用資格將被

取消﹕

    - 購買發票有任何非認可之刪改;
    - 產品被用作商業或工業用途;
    - 產品經非認可之技術人員改裝或
      加裝任何配件;
    - 機身編號被擅自塗改、破壞或刪除。

4.  如用戶自攜熱水器或部份配件到本公

司維修部檢查或維修,本公司將會收
取檢查或測試費用。

5.  總代理有權選擇維修或更換配件或其

損壞部份。

6. 產品一經被轉讓,其保用即被視作無

效。

7.  香港客戶:
     保用只在香港、九龍及新界區有效,

東涌、愉景灣及離島須額外收取交通
費用。

    國內客戶:
    個別區域或會收取額外交通費用,詳情

請致電全國服務熱線查詢。

 

1. 

未能出示購買發票正本者,將不獲免

費維修服務。

2. 

用戶應依照說明書的指示操作。本保

用並不包括﹕

   - 任何附件及輔助裝置﹔
   - 因天然或人為意外造成的損壞 
     (包括運輸及其它)﹔
   - 電源接合不當、不依說明書而錯誤 
     或疏忽使用本機所引致的損壞。

3. 

於下列情況下,用戶之保用資格將被

取消﹕

   - 購買發票有任何非認可的刪改;
   - 產品被用作商業或工業用途;
   - 產品經非認可的技術人員改裝或
     加裝任何配件;
   - 機身編號被擅自塗改、破壞或刪除。

4. 

如用戶自攜熱水器或部份配件到本公

司維修部檢查或維修,本公司將會收
取檢查或測試費用。

5. 

總代理有權選擇維修或更換配件或其

損壞部份。

6. 

產品一旦被轉讓,其保用即被視作無

效。

7. 

香港客戶:

   保用只在香港、九龍及新界區有效,

東涌、愉景灣及離島須額外收取交通
費用。

   國內客戶:
   個別區域或會收取額外交通費用,詳情

請致電全國服務熱線查詢。

 

此保用提供德國寶產品的機件在正常使
用下壹年保用(自購買日起計算)。

用戶須在購機十天內,以下列其中一種
方式向本公司登記資料,保用手續方正
式生效﹕

1) 

填妥本公司網頁內的保用登記表格      

www.germanpool.com/warranty

2) 

填妥保用登記卡,並連同購機發票的

副本一併郵寄到客戶服務總部 (本公
司將不發還發票副本或登記卡)。 

Under normal operations, the water heater will 

receive a 1-year full warranty provided by German 

Pool (effective starting from the date of purchase).

This warranty is not valid until Customer’s 

registration information is returned to and 

received by our Service Centre within 10 days 

of purchase via one of the following methods:

1) Visit our website and register online:       

www.germanpool.com/warranty

2) Complete all fields on the attached Warranty 

Card and mail it back to our Customer Service 

Headquarters along with a photocopy of the 

purchase invoice (Warranty Card and invoice 

copy will not be returned to Customer)

1. Customer who fails to present original 

purchase invoice will be disqualified for 

free warranty.

2. Customer should always follow the 

operating instructions. This warranty does 

not apply to:

    - any accessories and auxiliary devices;

    - damages caused by accidents of any kind   

      (including transport and others); 

    - operating failures resulted by incorrect   

      voltage, improper operations and  

      unauthorized installations or repairs.
3. This warranty is invalid if:

    - purchase invoice is modified by 

      unauthorized party;

    - product is used for any commercial or 

      industrial applications;

    - product is repaired or modified by 

      unauthorized personnel, or unauthorized 

      parts are installed;

    - serial number is modified, damaged or  

      removed from the product.
4. Regardless of warranty status, all walk-in 

requests for water heater repair or 

replacement service at our Customer 

Service Centre are subject to testing and 

handling charges.

5. German Pool will, in its discretion, repair or 

replace any defective part. 

6. This warranty will be void if there is any 

transfer of ownership from the original 

purchaser.

7. Hong Kong: Service area includes Hong 

Kong Island, Kowloon and New Territories. 

Repairs in Tung Chung, Discovery Bay or 

other outlying islands are subject to extra 

service charges. 

    Mainland China: Repairs in certain regions 

are subject to extra service charges. 

Please call our China Customer Service 

Hotline for enquiries.

 

Summary of Contents for crx9

Page 1: ...Instantaneous Water Heater CRX9 Please read these instructions and warranty information carefully before use and keep them handy for future reference WH CRX M 10 2 Printed in Germany WH CRX M 11 3...

Page 2: ...inal rating and serial number Pos Description 1 Brass connection set with back flow prevention in hot water outlet 2 Heating element 3 Display panel 4 Safety thermal cut out Pos Description 5 Electron...

Page 3: ...ed conductor cross section 3 6 0mm2 Factory preset flow reducer 5 0 l min Increase of temperature t at present flow 23K Hot water temperature at 20 C inlet temp 43 C Switch on flow rate 2 l min Temper...

Page 4: ...inlet temperature must not exceed 30 C In case of malfunction disconnect the fuses immediately In case of leaks cut off the cold water supply instantly Repairs must only be carried out by the customer...

Page 5: ...cooled again and valuable energy will be lost Moreover the cold water added in the fitting cannot be controlled by the elec tronics and a constant temperature can no longer be guaranteed Maintenance...

Page 6: ...nec tion piece positionI 6 Vent the unit by carefully opening and closing the af filiated warm water tap valve several times until air no longer emerges from the pipe Cleaning the fine filter surface...

Page 7: ...and serial number please Problem Possible Cause Solution LED remains off water remains cold Circuit breaker tripped Have the fault rectified and reset The pilot lamp Power lights water remains cold He...

Page 8: ...connections of the wall Mark the drill holes and drill them using a 6 mm drill 5 Mount the unit to the wall and connect the water supply of the unit together with the 3 8 seals 6 Open the water suppl...

Page 9: ...then be screwed into the 3 8 union nut of the appliance and delivery pipe together with the 3 8 seals 6 Mark the drill holes and drill them using a 6 mm drill Mount the unit to the wall and connect t...

Page 10: ...ppliance complies with protection type IP25 and may be installed in zone 1 acc IEC In order to avoid thermal losses the distance between the heater and the tapping point should be as small as possible...

Page 11: ...insert the connecting lead The lead must be secured with the cable clamp when using a flexible power cord 5 Screw the appliance into position using the enclosed raw plugs and screws 6 Install the appl...

Page 12: ...water supply and slowly open the shutoff valve 10a in the cold water connection position I if necessary Check all connections for leaks 10 Next open and close the hot water tap several times until no...

Page 13: ...be slightly smaller than the cross section of the cable in order to ensure optimum protection against water Fit the grommet into the opening The protection grommet must be used The appliance must be e...

Page 14: ...14 CRX9 1 1 7 2 3 4 5 6 1 2 3 4 STB 5 6 7...

Page 15: ...5 CRX9 2 1 14 2 15 3 15 4 16 18 5 19 6 20 25 38 39 3 CRX9 0 2 l 0 6 MPa 6bar 8 0 9 6kW 50Hz 1N PE 220 240 V 36 40A 3 6 0mm2 5 0 t 23K 20 43 2 35 55 30 1 2 B S P H W D 2 2kg 33 21 9cm VDE 1 IP25 GEFAHR...

Page 16: ...16 CRX9 4 43 30 GEFAHR 15 Power 2 Pressure 3 5 35 55 4 Power 2 Overheat 1 1 2 4 5 3...

Page 17: ...17 CRX9 1 2 1 3 4 GEFAHR...

Page 18: ...18 CRX9 4 GEFAHR II I 10a 10c 10b 10 1 II 10a 2 10b 10c 3 4 5 I 6 10 1 2 10 d 3 4 5 6 10d...

Page 19: ...19 CRX9 GEFAHR 5 German Pool LED Power Pressure...

Page 20: ...20 CRX9 6 1 2 12 mm 12 mm 3 P T F E 1 2 4 6 mm 5 3 8 6 10 a I 7 CRX 9 2...

Page 21: ...21 CRX9 6 1 2 1 2 1 2 1 2 3 1 2 4 10 d 5 3 8 3 8 6 6 mm 7 8 10 a 9 10d...

Page 22: ...22 CRX9 6 GEFAHR GEFAHR IP25 IEC 1 2 m 3 bar 6 bar...

Page 23: ...23 CRX9 6 1 2 3 6 mm 4 5 6 7 P T F E 8...

Page 24: ...24 CRX9 6 II I 10a 9 I 10 a 10...

Page 25: ...25 CRX9 6 GEFAHR I 1 3 mm 2 3 4 5 6 German Pool www germanpool com...

Page 26: ...26 CRX9 1 1 7 2 3 4 5 6 1 2 3 4 STB 5 6 7...

Page 27: ...X9 2 1 26 2 27 3 27 4 28 30 5 31 6 32 37 38 39 3 CRX9 0 2 l 0 6 MPa 6bar 8 0 9 6kW 50Hz 1N PE 220 240 V 36 40A 3 6 0mm2 5 0 t 23K 20 C 43 C 2 35 55 C 30 C 1 2 B S P H W D 2 2kg 33 21 9cm VDE 1 IP25 GE...

Page 28: ...28 CRX9 4 43 C 30 C GEFAHR 15 Power 2 Pressure 3 5 35 C 55 C 4 Power 2 Overheat 1 1 2 4 5 3...

Page 29: ...29 CRX9 1 2 1 3 4 GEFAHR...

Page 30: ...30 CRX9 4 GEFAHR 10 1 II 10a 2 10b 10c 3 4 5 I 6 10 1 2 10d 3 4 5 6 II I 10a 10c 10b 10d...

Page 31: ...31 CRX9 GEFAHR 5 German Pool LED Power Pressure...

Page 32: ...32 CRX9 6 1 2 12 mm 12mm 3 P T F E 1 2 4 6 mm 5 3 8 6 10a I 7 CRX9 2...

Page 33: ...33 CRX9 6 1 2 1 2 1 2 1 2 3 1 2 4 10d 5 3 8 3 8 6 6 mm 7 8 10a 9 10d...

Page 34: ...34 CRX9 6 GEFAHR GEFAHR IP25 IEC 1 2 m 3 bar 0 6 MPa 6 bar...

Page 35: ...35 CRX9 6 1 2 3 6mm 4 5 6 7 P T F E 8...

Page 36: ...36 CRX9 6 9 I 10a 10 II I 10a...

Page 37: ...37 CRX9 6 GEFAHR I 1 3mm 2 3 4 5 6 German Pool www germanpool com...

Page 38: ...y 2 Customer should always follow the operating instructions This warranty does not apply to any accessories and auxiliary devices damages caused by accidents of any kind including transport and other...

Page 39: ...k Road Tokwawan Kowloon H K Tel 852 2333 6249 Fax 852 2356 9798 Email Address repairs germanpool com 116 2 4 852 2333 6249 852 2356 9798 repairs germanpool com China 86 400 830 3838 86 0757 2336 0284...

Page 40: ...be prosecuted 852 2333 6245 852 2773 2888 info germanpool com 116 2 4 116 2 4 852 2765 8215 852 2365 6009 Tel Fax E mail German Pool Hong Kong Limited Room 2 4 Upper Ground Floor Newport Centre 116 M...

Reviews: