al
730<CR><LF>
>
Read Software Version
AT+VERSIONS?<CR><L
F>
<CR><LF>+VERSIONS
=v1.13190619<CR><LF
>
Read Hardware Version
AT+VERSIONH?<CR><L
F>
<CR><LF>+VERSIONH
=SAA-0267-01-9703-
03<CR><LF>
Read Optical Port Frame
Note*
AT+FRAME?<CR><LF>
<CR><LF>+FRAME=30
0,7,E,1<CR><LF>
Set Optical Port Frame
Note*
AT+FMETER=9600,8,N,1
<CR><LF>
<CR><LF>OK<CR><LF
>
Read Working Mode
TRANSPARENT , IEC
AT+MODE?<CR><LF>
<CR><LF>+MODE=IEC
<CR><LF>
Set Working Mode
TRANSPARENT , IEC
AT+MODE=IEC<CR><L
F>
<CR><LF>OK<CR><LF
>
Read Automatic Power
Off Time (Minute)
1 to 10
AT+AUTOTIME?<CR><
LF>
<CR><LF>+AUTOTIME
=1<CR><LF>
Set Automatic Power Off
Time (Minute)
1 to 10
AT+AUTOTIME=3<CR>
<LF>
<CR><LF>OK<CR><LF
>
Note*:
Set up and read the optical port frame as follows:
•
Baud rate, Number of Bit, Parity, Stop bit
The value of each parameters is as follows:
•
Baud rate: 300, 1200, 2400, 4800, 9600, 19200
•
Number of Bit: 7, 8
•
Parity: N (none), E (even), O (odd)
According to the above description, if we want to connect with the meter with baud rate: 4800
and number of bit: eight and parity: E with the last 1 bit, the command format will be as follows:
➢
AT+FMETER=4800,8,N,1<CR><LF>
Note:
For meters that comply with IEC 62056-21 standard, the command should be:
➢
AT+FMETER=300,7,E,1<CR><LF>
Upgrading Firmware
To upgrade the OP-730 firmware, the "QFlash_V4.0" program is used. After executing the EXE,
the window will opens as shown below: