Display
The illuminated graphic LCD display with self-charging battery lets you change fixture
settings even when the power is off. See Chapter 6 for settings, readouts, and related
information.
You can adjust the contrast and brightness of the display in the
Display
menu in the
control panel. You can also invert the display for easier reading if the fixture is flown
head-down in a rig, and you can set the display to flash if the DMX signal to the fixture
is lost, giving a discreet indication of DMX signal status.
Cooling modes
Cooling fans can be set to one of two modes:
•
Auto
for temperature-regulated operation. This mode optimizes cooling for
quietness.
•
High
for constant high-speed operation. This mode minimizes the possibility that the
fixture will reduce its light output if it exceeds thermal safety limits. This will normally
only happen when the fixture is worked hard for extended periods in high ambient
temperatures.
Fixture information
The
Information
menu in the control panel gives access to a long list of information
items. You can see a list of any internal errors that the fixture may have detected,
check main and distributed software and hardware versions, check temperature
sensor readouts, see logs of operating hours and boot count and check whether the
fixture is running on AC mains or battery power.
You can monitor the DMX values being received on the main DMX channels, and you
can monitor cooling fan operation.
Manual control
The
Manual Control
menu in the control panel lets you reset the entire fixture, reset tilt
only, or reset left or right LED drivers only. It also lets you control the main functions of
the fixture without DMX.
Test sequences
The
Test
menu lets you run test sequences to ensure correct operation of Tilt movement
only, color output from the RGB LEDs on the Plates only, or the entire fixture.
Service menu
The
Service
menu is password-protected and is intended for use by GLP Service.
Clamp attachment
The base provides Camlock attachment points for easy fastening of an omega clamp
attachment bracket that accepts two half-coupler clamps.