background image

 

 

 

GLP 

 German Light Products GmbH 

                        

  

(Instruction version 1.01) / from software version 1.02

 

5

 

1.1 

Safety Instructions  

 

 

The

 

 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e

 

 

is an advanced technology product. 

To  guarantee  smooth  operation,  it  is  necessary  to  follow  the 
following instructions. 

The  manufacturer  of  this  device  will  not  take  responsibility  of 
damages  through  any  disregard  of  the  information  in  this  user 
manual.  Warranty  claims  will  also  be  cancelled  in  the  event  of 
the system casing being opened. 

1.  Make  sure  that  before  powering  up  the  fixture,  the  fans  and  air  inlets  are 

clean and not blocked by anything. 

2.  Before  powering  up  the  fixture,  ensure  that  the  moving  head  part  of  the 

fixture can rotate unhindered through its full range of movement.  

3.  A  safety  distance  of  at  least  0.5  m  to  any  easily  flammable  material  (e.g. 

decoration material) must be adhered to.  

4.  Attention! Don’t touch the device during operation. Parts of the fixture can 

become hot and can cause injuries and / or damages.  

5.  Use only one DMX Input / Output at the same time.  

6.  Never look directly into the beam of light or one of the LEDs. Never use 

optical  apertures  with  a  distance  less  than  0.5  m  to  observe  the  beam  of 

light. LED Class 2M. Not following these precautions can result in serious 

injury to your eyes and in particular, your retina.    

 

Attention: LED Class 2M can cause injuries of your eyes even 
without optical instruments in front of them or within a distance 
of less than 0.5m and short exposure time.   

 

Avoid direct radiation to your eyes!   

7.  To  ensure  proper  operation,  you  must  also  follow  the  installation  guide 

described in chapter 2 of this manual. Operating the 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e

 

 

without suitable mounting devices can increase the risk of an accident. 

8.  The 

I

I

m

m

p

p

r

r

e

e

s

s

s

s

i

i

o

o

n

n

 

 

W

W

a

a

s

s

h

h

 

 

o

o

n

n

e

e features a unique small and lightweight design 

with  no  specific  carrying  handles.  Care  needs  to  be  shown  when  handling 

the  fixture  to  ensure  that  no  unnecessary  damage  should  occur.  Fragile 

areas  include  the  LCD  display  and  cover  on  one  side  arm  and  the  front 

bezel.  Pressure  in  these  areas  could  result  in  damages  which  will  not  be 

covered by the standard warranty. 

9.  Repair,  maintenance  and  installation  work  should  only  be  performed  by 

qualified  or  GLP  certified  staff.  You  need  to  pay  attention  to  the  common 

Summary of Contents for impression Wash One

Page 1: ...Instruction Manual from software version 1 02 Instruction version 1 01 e mail service glp de Internet http www glp de ...

Page 2: ...GLP German Light Products GmbH Instruction version 1 01 from software version 1 02 2 Notes ...

Page 3: ...ounting on the floor upright 7 2 1 1 Mounting in hanging position Head down 8 2 1 2 Mounting in sideways position 8 2 2 Securing the device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 9 3 The Menu Field 10 4 4 Maintaining and Cleaning the I Im mp pr re es ss si io on n W Wa as sh h o on ne e 18 4 1 Safety regulations 18 4 2 Maintenance Intervals rule of thumb 18 5 Technical Specifications 1...

Page 4: ...phical menu data entry 5 Base with various connectors and Camlock mounting system 6 DMX Output 5 Pin 7 DMX Output 3 Pin 8 Micro fuse 6 3x32mm T8A 9 Power Switch 10 2x Safety wire points 11 Neutrik Powercon Mains power input 12 Blank panel primed for Ethernet 13 DMX Input 3 Pin 14 DMX Input 5 Pin Note Only connect one cable to the DMX Input Output at the same time Base Side 1 10 6 7 8 9 10 Base Sid...

Page 5: ...to the beam of light or one of the LEDs Never use optical apertures with a distance less than 0 5 m to observe the beam of light LED Class 2M Not following these precautions can result in serious injury to your eyes and in particular your retina Attention LED Class 2M can cause injuries of your eyes even without optical instruments in front of them or within a distance of less than 0 5m and short ...

Page 6: ...ion on the system will terminate all warranty claims 11 Please keep this instruction manual for future reference 2 Preparation and Installation 2 1 Mounting The I Im mp pr re es ss si io on n W Wa as sh h o on ne e is fully operational whether it hangs or is mounted to a wall It can also be operated while standing on the floor Keep a safety distance of 0 5 m from any easily inflammable materials d...

Page 7: ...will ensure a safe and firm installation 2 1 1 Mounting on the floor upright To operate the I Im mp pr re es ss si io on n W Wa as sh h o on ne e in an upright position please use the dedicated floor stand which is shipped with all original fixtures The floor stand is mounted to the base of the fixture using the two Camlock quarter turn fasteners Line up and engage the camlock connectors from the ...

Page 8: ...n sideways position To operate the I Im mp pr re es ss si io on n W Wa as sh h o on ne e in a sideways position please use an additional mounting bar available from GLP or one of their agents This mounting bar is fixed via the four camlock quick release connectors Two half couplers or clamps are then used to hang fixture This technique is necessary to cope with the additional torque in this mounti...

Page 9: ...ty wire is securely fastened through the fixture and the fixtures mounting support Install a safety wire that can hold at least 10 times the weight of the fixture 2 3 Connections 2 3 1 Power Supply Autosensing 100 240 Volt AC 50 60 Hz earth contact type plug via Powercon Connected load 450 VA W T8A micro fuse 6 3x32mm Disconnect from the mains supply before changing the fuse and use only the above...

Page 10: ...yer 2 Layer 3 Layer 4 Notes DMX Start Address Set the DMX start address Personality Pan Tilt Pan Tilt settings Pan invert Selects Inverse Pan on or off Tilt invert Selects Inverse Tilt on or off Feedback Automatic position feedback selection for pan tilt movement Color Dimmer Curve Set the Dimmer Curve DMX Address Set the DMX start address Mode Allows selection of the desired DMX Mode Compressed F...

Page 11: ...tate automatically Display Inv Display will rotate manual Brightness Display backlight Set Default Resetting all functions to original values Status Version Shows the current software version Reset Hardware Hardware reset adjust All Reset all boards Head Reset only headboard FZE Reset only Focus Zoom Pan Reset only Pan Tilt Reset only Tilt Temperatures Display all temperatures LED Info Display the...

Page 12: ...tantaneous value for focus Beam Shaper Instantaneous value for shaper size Beam Shaper Size Instantaneous value for beam shaper DMX Quality Shows the DMX Quality Service Adjust Enter Code Adjustments for all functions Use code to enter calibration only for authorized persons with code Pan Adjust for pan Tilt Adjust for tilt Beam Shape Arm Adjust for Beam Shaper arm Beam Shape Rot Adjust for Beam S...

Page 13: ... temp 3200K 104 111 68 6F 41 43 5 White Color temp 5600K 112 119 70 77 44 46 5 White CTB Color temp 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 128 80 50 Rainbow Effect slow fast 129 223 81 DF 51 88 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 Shutter Shutter closed 0 15...

Page 14: ... PAN 96 127 60 7F 38 50 Circle size phase see also PAN 128 159 80 9F 51 62 Circle inverse size phase see also PAN 160 191 A0 BF 63 75 Lying eight size phase see also PAN 192 223 C0 DF 76 87 Random movement size see also PAN 224 255 E0 FF 88 100 14 Speed Pan Tilt relative movement 0 1 00 01 0 0 5 Pan Tilt Pan Tilt slow fast Use this channel 14 also for the speed of the movements channel 13 Pan Min ...

Page 15: ...temp 5600K 112 119 70 77 44 46 5 White CTB Color temp 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 128 80 50 Rainbow Effect slow fast 129 223 81 DF 51 88 6 Red Color mixing system Red 0 100 0 255 00 FF 0 100 7 Green Color mixing system Green 0 100 0 255 00 FF 0 100 8 Blue Color mixing system Blue 0 100 0 255 00 FF 0 100 9 Shutter Shutter closed 0 15 00 0F 0 5 5 Shutter pulse random slow fast 16...

Page 16: ... temp 7200K 120 127 78 7F 47 49 5 Rainbow Effect Stop 128 80 50 Rainbow Effect slow fast 129 223 81 DF 51 88 6 Red coarse Color mixing system Red 0 100 0 255 00 FF 0 100 7 Red fine Color mixing system Red low 0 255 00 FF 0 100 8 Green coarse Color mixing system Green 0 100 0 255 00 FF 0 100 9 Green fine Color mixing system Green low 0 255 00 FF 0 100 10 Blue coarse Color mixing system Blue 0 100 0...

Page 17: ...io on n W Wa as sh h O On ne e will then begin from that color and execute the rainbow effect synchronously Different I Im mp pr re es ss si io on n W Wa as sh h O On ne e can have different start colors but will still execute the rainbow effect synchronously If you choose a color different from the ones marked with 1 in the tables above the rainbow start color will be red 2 Rainbow effect Stop wi...

Page 18: ...lean the fixture or its lenses 4 1 Safety regulations Disconnect the fixture from the mains power before commencing any maintenance work Wait minimum 15 minutes after removing the power to allow the fixture to cool down 4 2 Maintenance Intervals rule of thumb The maintenance schedule of any given fixture depends on the installation environment Hence no specific guidelines can be given The cleaning...

Page 19: ...Chipset Lifetime 20 000 h Shutter Dimmer 8 16 Bit Strobe Effect with variable speed between 1 50 flashes per second Random strobe Pulse effects Continuous dimmer 0 100 Zoom 8 16 Bit Zoom range 3 60 Focus 8 16 Bit Motor driven focus from near 2 mtr to infinity DMX Control Standard USITT DMX 512 3 5 pole XLR Pin 3 Pin 2 Ground Pin 1 Pan Tilt 8 16 Bit 3 phase stepper motor Pan movement 540 Position F...

Page 20: ...eübersicht 4 H Half couplers clamps 8 I Internet 1 L LED Class 2M 5 M Maintenance 18 Menu Field 10 Menüfeld 10 Micro fuse 9 Mode key 10 Mounting 6 Mounting in hanging Position 8 Mounting on the Floor 7 O Optical parts 18 P Pan Movement 19 Power Supply 9 Powercon Netzanschluss 4 S Safety distance 6 Safety Instructions 5 Secure the Device 9 Software Version 1 T Tilt Movement 19 U Up Down keys 10 V V...

Page 21: ...GLP German Light Products GmbH Instruction version 1 01 from software version 1 02 21 ...

Reviews: