Gerber Prime GPB-7000 Manual Download Page 7

 

 

Troubleshooting

                                 

 

Symptom

 

Cause of Failure

 

Recommendation

 

The switch does not 
work and the LED is off

 

1.

 

The Switch is not 
plugged into the 
electrical outlet 
properly

 

2.

 

The Switch break 
down

 

1. 

Check power connections

 

2. Don’t open up the Switch and 

send it for repair.

 

The LED illuminates, but 
cannot turn ON or OFF 
the

 

switch

 

1. Check if the load 

plugged into the 
Switch has its own 
ON/OFF switch

 

2. Not carry out 

association

 

3. Same frequency 

interference

 

1. Set the ON/OFF switch of the load 

attached to ON

 

2. Carry out association

 

3.Wait for a while to re-try

 

LED keep flashing, but 
cannot control

 

Overload occurs

 

Remove the load attached or check 
max. load cannot exceed 16.0A

 

 

Specification

 

Operating Voltage

 

100-240VAC 50/60Hz 16A

 

Rated Voltage 

 

220-240Vac 50Hz (EU), 120Vac 60Hz (US), 230Vac 50Hz (IL), 

 

100Vac 50/60Hz (JP)

 

Maximum Load

 

16A (Resistive Load)

 

Range

 

Minimum 40M in door and 100M in outdoor line of sight

 

Operating Temperature

 

0°C ~ 40°C (85% humidity)

 

Storage Temperature 

-20 C ~ 60°C

 

Location 

 

Indoor use only

 

Frequency Range

 

868.40MHz; 869.85MHz(EU) 

 

908.40MHz; 916.00MHz(USA/Canada)

 

916MHz (Israel)

 

 

 

** Specifications are subject to change and improvement without notice.                           

 

FCC ID :

 

2AQO4GPB-7000

 

 

 

Warning:

 

1.Plug out to disconnect from power supply; Do not plug in line.

 

 

2. Do not exceed the max rating

 

 

Choosing a Suitable Location

 

 

1. 

Do not locate the switch facing direct sunlight, humid or dusty place.

 

2. 

The suitable ambient temperature for the Switch is 0°C~40°C.

 

3. 

Do not locate the Switch where exists combustible substances or any source of 

heat, e.g. fires, radiators, switch etc.

 

4. 

After putting it into use, the body of switch will become a little bit hot of which 

phenomenon is normal.

 

 
 

 

DANGER

   

Danger of electrocution!

 

All works on the device may be performed only by a qualified and licensed 

electrician. Observe national regulations. 

 

Any works introducing changes into the configuration must be always performed with 

disconnected voltage. 

 

 
 
 
 
 

Summary of Contents for GPB-7000

Page 1: ...ather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT In...

Page 2: ...again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means ex...

Page 3: ...the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class GPB 7000 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH...

Page 4: ...0x08 Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power...

Page 5: ...sion 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power fa...

Page 6: ...the Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the set...

Page 7: ...40M in door and 100M in outdoor line of sight Operating Temperature 0 C 40 C 85 humidity Storage Temperature 20 C 60 C Location Indoor use only Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00M...

Page 8: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter...

Reviews: