background image

 

 
 
Installation and Operation

 

 

1.  Plug this switch into a wall box near the load to be controlled. 

2.  Connects the load to the switch. Make sure the load to be controlled cannot exceed 

16A (Resistive Load). 

3.  Press the button or switch on the load to the ON position. 

4.  To manually turn ON the switch, short press the “

” button. The green “

” LED will 

turn ON, and the blue timer LEDs will also turn ON. Every passed 10 minutes will 

change one blue LED as a green LED. When all the blue LEDs changes, all the 

green LEDs will blink twice and turn off. Then the switch turns off and green “

” 

LED changes to red “

” LED. 

5.  To manually turn OFF the Switch, short press the “

” button. The red LED will turn 

ON and the load connected to the switch will also turn OFF. 

6.  Every short press “

” button, there will be increasing one more blue LED. When 

arrives to the intended timer, stop pressing and all the blue LEDs will blink twice. 

Or you can press and hold “

” button, there will be increasing one more blue LED 

every half second. Every blue LED represents 10 minutes working time of switch. 

The maximum time is 110 minutes, and the default is 60 minutes.   

7.  Every short press “

” button, there will be decreasing one blue LED. This means 

the working time of switch decrease 10 minutes. The minimum time is 10 minutes. 

Or you can press and hold “

” button, there will be decreasing one blue LED every 

half second.

 

8.  After switch is turned on for a while, you can still decrease (or increase) the working 

time by pressing “

” button (or “

” button). When all the blue LEDs decreases to 

off, the switch will turn off.

 

 

Programming

 

 

1.    Basic Command Class / Binary Switch Command Class

 

GPB-7000 will respond to BASIC and BINARY commands that are part of the Z-
Wave system.

 

 

1-1 BASIC_GET / BINARY_SWITCH_GET

 

        Upon receipt of the following commands from a Z-Wave Controller, GPB-7000 will 

report its On/Off state to the node asked.

 

 

Basic Get Command: [Command Class Basic, Basic Get]

 

Basic Report Command:

 

Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]

 

Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]

 

 

Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get]

 

Binary Switch Report Command:

 

Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 
=0(0x00)]

 

Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 
255(0xFF)]

 

 

1-2 BASIC_SET / SWITCH_BINARY_SET

 

        Upon  receipt  of  the  following  commands  from  a  Z-Wave  Controller,  the  load 

attached to GPB-7000will turn on or off.

 

 

[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)]: the load attached 
to the switch turns on.

 

[Command  Class  Basic,  Basic  Set,  Value  =  0(0x00)]:  the  load  attached  to  the 
switch turns off.

 

[Command Class Switch Binary, Switch Binary Set, Value = 1~99, (255)0xFF]: the 
load attached to the switch turns on. 
[Command  Class  Switch  Binary,  Switch  Binary  Set,  Value  =  0(0x00)]:  the  load 
attached to the switch turns off. 

 
1.  Z-Wave’s Groups (Association Command Class Version 2) 
 

The Switch can be set to send reports to associated Z-Wave devices.    It supports one 

association group with one node support for Grouping 1. For group 1, the Switch will 

report its latest status to Z-Wave Controller.   
 
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, 
ALARM_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION. 
 

2-1 Auto report to Grouping 1 (Maximum Node 5) 

Summary of Contents for GPB-7000

Page 1: ...ather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT In...

Page 2: ...again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means ex...

Page 3: ...the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class GPB 7000 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH...

Page 4: ...0x08 Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power...

Page 5: ...sion 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power fa...

Page 6: ...the Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the set...

Page 7: ...40M in door and 100M in outdoor line of sight Operating Temperature 0 C 40 C 85 humidity Storage Temperature 20 C 60 C Location Indoor use only Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00M...

Page 8: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter...

Reviews: