6
3-1 Manual switch report mode
When GPB-7000 is turned on or turned off, it will send a Switch_Binary_report to the
nodes of group1. If the setting value is 0, it will disable sending the report.
3-2 switch Working Timer
This is a working time for the switch from turn to turn off. The maximum setting
value is from 11(11*10min=110min), and the default value is 6.
3-3 W
att
Meter Report Period:
If the setting is configured for 1hour (set value =720), the GPB-7000 will report its
instant power consumption every 1 hour to Group1 node. The maximum interval
to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
3-4 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the GPB-7000 will report its
Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55
days (10min*32767/1440=227.55 days).
3-5 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 1500, when the load current of Relay1 over this value, GPB-7000
will send current meter report to warn the Group1 node, the Range of the setting
value is from 10 to 1500, and the default value is 1500.
3-6 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 over
this value, GPB-7000 will send KWH meter report to warn the Group1 node,
minimum value is 1KWh and default value is 10000 kWh.
3-7 Watt differential report mode:
Whenever the instant power consumption varies over 5%, it will report its instant
power consumption to Group1 node. If the setting value is 0, it will disable sending
the report.
4. Firmware update over the air (OTA)
GPB-7000 is based on 500 series SoC and supports Firmware Update Command
Class, it can receives the updated firmware image sent by controller via the Z-wave
RF media. It is a helpful and convenient way to improve some function if needed.
5. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_ZWAVEPLUS_INFO
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
* COMMAND_CLASS_SECURITY0
* COMMAND_CLASS_SECURITY2
* COMMAND_CLASS_DEVICE_RESET_LOCALLY
* COMMAND_CLASS_ASSOCIATION_V2
* COMMAND_CLASS_ASSOCIATION_GRP_INFO
* COMMAND_CLASS_POWERLEVEL
* COMMAND_CLASS_SWITCH_BINARY
* COMMAND_CLASS_BASIC
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_CONFIGURATION
* COMMAND_CLASS_ALARM
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2