background image

 

 

3-1 Manual switch report mode

 

When GPB-7000 is turned on or turned off, it will send a Switch_Binary_report to the 

nodes of group1. If the setting value is 0, it will disable sending the report. 

 

3-2 switch Working Timer

 

This is a working time for the switch from turn to turn off. The maximum setting

 

value is from 11(11*10min=110min), and the default value is 6.

 

3-3 W

att 

Meter Report Period:

 

    If the setting is configured for 1hour (set value =720), the GPB-7000 will report its 

instant power consumption every 1 hour to Group1 node.    The maximum interval 

to report its instant power consumption is 45 hours (5s*32767/3600=45hr).

 

3-4 KWH Meter Report Period:

 

      If  the  setting  is  configured  for  1hour  (set  value  =6),  the  GPB-7000  will  report  its 

Accumulated  Power  Consumption  (KW/h)  every  1  hour  to  Group1  node.    The 

maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 

days (10min*32767/1440=227.55 days).

 

3-5 Threshold of current for Load Caution

 

This is a warning when the current of load over the preset threshold value, if the

 

setting value is 1500, when the load current of Relay1 over this value, GPB-7000

 

will send current meter report to warn the Group1 node, the Range of the setting

 

value is from 10 to 1500, and the default value is 1500.

 

3-6 Threshold of KWh for Load Caution

 

This is a warning when the KWh of load over the preset threshold value, If the

 

setting value is 10000, when the Accumulated Power Consumption of Relay1 over 

 

this value, GPB-7000 will send KWH meter report to warn the Group1 node,

 

minimum value is 1KWh and default value is 10000 kWh.

 

3-7 Watt differential report mode:

 

  Whenever the instant power consumption varies over 5%, it will report its instant 

power consumption to Group1 node. If the setting value is 0, it will disable sending 

the report.

 

 

4. Firmware update over the air (OTA)

 

GPB-7000 is based on 500 series SoC and supports Firmware Update Command 

Class, it can receives the updated firmware image sent by controller via the Z-wave 

RF media. It is a helpful and convenient way to improve some function if needed.

 

 

5. Command Classes

 

The Switch supports Command Classes including…

 

* COMMAND_CLASS_ZWAVEPLUS_INFO

 

* COMMAND_CLASS_VERSION

 

* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

 

* COMMAND_CLASS_SECURITY0

 

* COMMAND_CLASS_SECURITY2

 

* COMMAND_CLASS_DEVICE_RESET_LOCALLY

 

* COMMAND_CLASS_ASSOCIATION_V2

 

* COMMAND_CLASS_ASSOCIATION_GRP_INFO

 

* COMMAND_CLASS_POWERLEVEL

 

* COMMAND_CLASS_SWITCH_BINARY

 

* COMMAND_CLASS_BASIC

 

* COMMAND_CLASS_METER_V3

 

* COMMAND_CLASS_CONFIGURATION 

 

* COMMAND_CLASS_ALARM

 

* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

 

 
 
 
 
 
 
 

Summary of Contents for GPB-7000

Page 1: ...ather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT In...

Page 2: ...again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means ex...

Page 3: ...the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class GPB 7000 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH...

Page 4: ...0x08 Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power...

Page 5: ...sion 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power fa...

Page 6: ...the Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the set...

Page 7: ...40M in door and 100M in outdoor line of sight Operating Temperature 0 C 40 C 85 humidity Storage Temperature 20 C 60 C Location Indoor use only Frequency Range 868 40MHz 869 85MHz EU 908 40MHz 916 00M...

Page 8: ...ations However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter...