GPB-7000 

 

Gerber Prime Boiler Control Panel 

 

 

 

 

 
 
 
 
 
 
 
 

 

 

Note: The power cord must meet 1.25mm² or 16AWG or better 

 

 

This Gerber Prime Boiler GPB-7000 is a security enabled wireless device, based on 
Z-Wave  Plus  technology.  Z-Wave  Plus

TM

  enabled  devices  displaying  the  Z-Wave 

Plus

TM

 logo can also be used with it regardless of the manufacturer, and can also be 

used in other manufacturer’s Z-Wave

TM

 enabled networks. Remote On/Off control of 

the  switch  is  possible  with  other  manufacturer’s  wireless  Controller.  GPB-7000  is 
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that 
the signal is received by its intended destination by routing the signal around obstacles 
and radio dead spots. Because GPB-7000 supports Security Command Class, it can 
learn  with  Secured  controller.  Its  functionality  and  supported  command  classes  is 
identical when included as a secure and non-secure device.

 

 

GPB-7000 is able to detect instance wattage (3840/EU, 1920/US) and overload current 

(16A) of connected lights or appliances. When detecting overload state, the switch will 
be  turned  off  and  its  On/Off  function  will  be  lockout  of  which  LED  will  flash  quickly.   
However,  disconnect  and  re-connect  the  switch  will  reset  its  overload  condition  to 
normal status.

 

 

Safety Precautions and Installation 

 

 

Avoid installing the unit in storming or raining weather. 

 

 

Be sure to isolate or switch off power source before installing or 
maintenance. 

 

 

Do ensure that the power supply circuit protected by a 16A circuit breaker or 
suitable equivalent fuse. 

 

IMPORTANT

 

 

Installation must be performed by skilled technicians who are informed about 
the standards and technical requirements of the appliance and its proper 
installation. 

 

 

Check your local codes as they apply to your situation. If the house wiring is 
of aluminum, consult with an electrician about proper wiring methods. 

 

Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING 
CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL 
SHOCK.   

 

 

Adding to Z-Wave

TM

 Network

 

 

In the front casing, there are thee touch buttons with LED indicator, “

”, which 

is used to toggle switch on and off or carry out inclusion, exclusion, reset. When first 
power  is  applied,  its  LED  flashes  on  and  off  alternately  and  repeatedly  at  2  second 
intervals. It implies that it has not been assigned a node ID. 

 

 

Smart Start

 

 

Before adding GPB-7000 into the Z-wave network, the controller should scan its QR

 

code. Then connect the AC power to GPB-7000, the learning procedure will progress

 

automatically.

 

 

Note:

    Unlike “inclusion” function as shown in the table below, the execution of 

smart start is free from pressing the On/Off button on the Switch.

 

 

The table below lists an operation summary of basic Z-Wave functions. Please refer 
to the instructions for your Z-Wave

TM

 Certificated Primary Controller to access the 

Setup function, and to Add/Remove/associate devices

 

Summary of Contents for GPB-7000

Page 1: ...ather Be sure to isolate or switch off power source before installing or maintenance Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse IMPORTANT In...

Page 2: ...again and hold for 5 seconds 3 IDs are excluded LED 2 second on 2 second off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means ex...

Page 3: ...the switch will turn off Programming 1 Basic Command Class Binary Switch Command Class GPB 7000 will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH...

Page 4: ...0x08 Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF Alarm Level 0xFF 2 2 Response to Meter Get Command The switch will report its 1 instant Power...

Page 5: ...sion 2 Scale 5 Size 2 Meter Value I Example Scale 0x05 I Precision 2 Size 2 Bytes I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 2 2 6 load power fa...

Page 6: ...the Range of the setting value is from 10 to 1500 and the default value is 1500 3 6 Threshold of KWh for Load Caution This is a warning when the KWh of load over the preset threshold value If the set...