GERATHERM GT-5907 Instruction Manual Download Page 3

GB

Precautionary measures

29

 •  This manual and the product are not substitutes for visit-

ing the doctor.

 

Neither the information contained herein nor this product 

may be used to diagnose or treat health problems, or to 
prescribe drugs. If you have or suspect that you have a 
medical problem, please seek immediate advice from 
your doctor.

 •  Do not conduct any measurements if the temperature is 

low (below +5 °C) or high (over +40 °C), or if the relative 
humidity is over 90 %, as this can lead to inaccurate read-
ings.

 •  Wait 30 to 45 minutes, before taking a measurement if you 

have just had a caffeinated drink or a cigarette.

 •  Relax for at least 5 to 10 minutes before taking a measure-

ment.

 •  Please wait 3 to 5 minutes between measurements, so 

that your blood vessels can return to the state they were 
in prior to measurement. You may have to adapt the wait-
ing time to your personal physiology.

 •  It is recommended that you use the same arm for each 

measurement (preferably the left) and take the measure-
ment at about the same time every day.

 •  Sit down comfortably with your elbows placed on the table 

and both feet on the ground. Please do not interlock your 

legs during the measurement.

 •  Wrap the cuff snug around your upper arm and lay your 

arm on a 

fl

 at surface at the same level as your heart.

 •  Take the measurement at room temperature in a quiet and 

stress-free environment.

 •  The unit should not be moved or shaken during the meas-

urement. Please do not speak during the measurement.

 •  Please keep in mind that blood pressure naturally varies 

depending on the time of day and is affected by many 
different factors. Blood pressure is usually highest at work 
and reaches its lowest level during the sleep phase.

 •  Blood pressure measurements should be assessed by a 

doctor or trained healthcare professional who is familiar 

with your medical history. If you use the unit and regularly 
record the results, please keep your doctor informed with 
regard to the ongoing changes in your blood pressure.

 •  If you suffer from a cardiovascular disease (such as 

atherosclerosis), diabetes, a liver or kidney disease, se-
vere hypertension or peripheral circulatory disorders, etc., 
please consult your doctor before using this unit.

 •  This unit is not suitable for use by people with cardiac 

arrhythmias.

Summary of Contents for GT-5907

Page 1: ...GB Digital Blood Pressure Monitor for the upper arm INSTRUCTION MANUAL GT 5907...

Page 2: ...inches Designated use 28 Precautionary measures 29 Warranty 31 Information you should know before operating the unit 31 About the unit Function description 32 Explanation of displays 33 Preparation f...

Page 3: ...down comfortably with your elbows placed on the table and both feet on the ground Please do not interlock your legs during the measurement Wrap the cuff snug around your upper arm and lay your arm on...

Page 4: ...esult in circulatory disor ders which can cause unpleasant sensations such as lo calised bleeding under the skin or temporary numbness in your arm These symptoms do not usually last long How ever if y...

Page 5: ...ressure level What about low blood pressure In general a lower blood pressure reading is better unless causes unpleasant symptoms such as fainting and or light headedness The warranty for this blood p...

Page 6: ...red automatically and non invasively which helps to ease the operation The Geratherm med control have 2 x 99 memories with date and time display a big LCD screen and arrhythmia detection The RCC radio...

Page 7: ...to fit arm sizes between 22 and 30cm 8 7 to 11 81 inches Explanation of displays access for power supply cuff On Off Button LCD Display Memory Date Time Systo lic Pulse Diasto lic Low Batterie Memory...

Page 8: ...e type of alkaline bat teries be used to avoid incompatibility Rechargeable batteries with a voltage of 1 2V are not suitable for this product Keep batteries away from small children Do not throw batt...

Page 9: ...or use AC adapter accessory Use the device only with a medical approved stabi lized AC adapter 6V DC 600mA Note 1 No batteries are required during operation using the AC adapter 2 If AC adapter power...

Page 10: ...ata received the machine enters Clock Mode and keeps the time and date un changed When the machine is in the RCC Mode you can skip RCC receiving and enter the Clock Mode by pressing START button b For...

Page 11: ...l clock adjusting if no RCC signal or weak signal a When the machine is in Clock Mode press the START and MEM button at the same time abt 2 sec the machine enters Forced RCC Receiving mode then press...

Page 12: ...the heartbeat during the pressure are falling down f After measurement the result of systolic diastolic and pulse rate will all display on LCD And irregu lar heartbeat symbol and blood pressure class...

Page 13: ...ssment diastolic pressure mmHg systolic pressure mmHg Severe Hypertension Grade 3 Moderate Hypertension Grade 2 Mild Hypertension Grade 1 Optimal Normal High Normal Blood pressure classification Systo...

Page 14: ...ress the MEM but ton previously memories will show by turns d All memories have the WHO classification and the COL OUR CHANGE LED will also indicate the blood pres sure classification e If it has no m...

Page 15: ...o not drop the unit It is not shock proof Do not modify or disassem ble the unit or the arm cuff Do not twist the arm cuff Use a cloth moistened with water or neutral detergent to clean the body of th...

Page 16: ...not be used for a long time Do not press the START button if the cuff has not been properly wrapped around the arm Care and maintenance It is recommended the cuff should be disinfected 2 times every w...

Page 17: ...serious arrhyth mia to use this blood pressure monitor LCD shows low battery symbol Batteries low Change the batteries Observe the applicable regulations when disposing of the device and batteries Thi...

Page 18: ...of measurement the pressure reading must be below 15 mm Hg LCD shows Er 7 EEPROM accessing error LCD shows Er 8 Device parameter check error LCD shows Er A Span error BPM no response when you press bu...

Page 19: ...80 pulse beats min Accuracy 3mmHg blood pressure 5 pulse rate Memory 2 x 99 times with time and date displaying Low Battery Indicator yes Auto Power Off after 1 minute Battery Life Approx 200 measurem...

Page 20: ...ometers part 3 Supplementary requirements for electromechanical blood pressure measuring systems EN 1060 4 Non invasive sphygmomanometers Part 4 Test procedures to determine the overall system accu ra...

Page 21: ...requirements for EMC electromagnetic compatibility and defines the levels of immunity to electromagnetic interference and the maximum electromagnetic emission levels for medical devices This blood pr...

Page 22: ...umidity should be at least 30 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 3 A m 3 A m Power frequency magnetic fields should be at levels character istic of a typical location in a typicalco...

Page 23: ...as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity ofequipment marked with the following symbol...

Reviews: