Mar .2018
GeraFold User Manual 14
User interface Gerafold 212
The Gerafold 212 control panel contains two buttons and
two indicator lights.
The red light shows a fault as a jam or that the folder is
busy, while the green light show the current folders
program.
The circular button when pressed during the
introduction or the folding process, stops
the movement of the engines, in case of
failure or red LED On, it operates as a reset
of the logic and verification status of the
folding machine.
The arrow key has different functions in the case of:
Selection
Key
Red LED is off and green LED is on, the
arrow key allows the folder program
selection.
Red LED on, by pressing for a long the
arrow key it performs the paper jam
ejection, the engine pushes the paper out
from the folding pocket where the sensor is
covered.
Red LED on but by pressing the arrow key
it does not activate the engine movement,
this means that paper jam is located at the
folder entry and must removed by pulling
back the copy by hand.
The metric fold standard programs P1,P2 ,P3 are selected when led 1.2.3
are steady green led on
The metric fold with binding margin programs P5,P6 ,P7 are selected when
led 1.2.3 are blinking green led on
The Custom fold programs P4,P8 are selected when led 4 is steady
orange led on
The Test program P9 , is selected when led 4 is off
Procedure to change feed speed
The feed the paper into the folder straight need attention, for this reason is
possible to customized entry speed to low, mid , high speed.
The folder default setup is mid speed.;
When user requires more time to ensure straight document feed into the
folder it’s possible to lower the speed to 6 meters per minute
When user requires less time to ensure straight document feed into the
folder and need more productivity it’s possible to upper the speed to 12
meters per minute .
Procedure to change feed speed: select program P9 led orange off, then
press and old arrow key over 4 seconds then release, after each pressof
arrow key change the number of green leds on according to below list.
Led green light on means
3 leds on 12m/min
2 leds on 09m/min
1 leds on 06m/min
After the selection pres reset to save and exit. Select a fold program to fold.
Summary of Contents for GeraFold 206
Page 1: ...GeraFold User Manual Revision March 2018...
Page 23: ...Mar 2018 GeraFold User Manual 23 Gerafold 218 sensor position S4 S3 C2 C3 S2 S1 S0 S5...
Page 26: ...Jan 2018 GeraFold User Manual 26 Manuel Utilisateur GeraFold R vision Mars 2018...
Page 49: ...Mars 2018 Manuale Utente GeraFold 49 Manuale Utente GeraFold Revisione Mar 2018...