The device has two cable entries, one on the side and one at the bottom of cabinet. 

 Side entry which is next to MCBs and alarm module is easier to access.  

 If bottom entry is preferred: 

o

 In models with drawers, there are no obstacles between terminals and entry or use 

cable spiral wrap as guide. 

o

 In models without drawers, use holes on battery shelves as cable guide. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for ARG-110 Series

Page 1: ...GEPA ARG Series Battery Charger with Battery Group User Guide...

Page 2: ...er or sales company is not responsible of faults if user doesn t obey recommendations at the above This is a Class A product In a domestic environment this product may cause radio interference in whic...

Page 3: ...age Supervising 4 2 6 DC Source Mode 4 2 7 Autonomous Battery Maintenance 4 2 7 1 TEDA Turkish Electricity Distribution Authority Method 4 2 7 2 Equalize Timer Mode Method 4 2 8 Surge Protective Devic...

Page 4: ...battery group capacity Wide input voltage tolerance Floating or equalizing charge Independent and adjustable battery charge and total system current output Electronic short circuit protection at DC o...

Page 5: ...al temperature controlled fan Fan is supplied from AC input and controlled by microcontroller according to digital temperature sensor measurement Operating temperature is adjustable 2 2 Battery Chargi...

Page 6: ...ing to Peukert s law This device is intended to use with AGM or gel VRLA batteries so coefficient is 1 1 Overload will trigger if total current output is limited at maximum current for 1 hour Over tem...

Page 7: ...ntenance Battery group should be checked periodically in order to ensure batteries are available to service The device has two different autonomous battery maintenance methods 2 7 1 TEDA Turkish Elect...

Page 8: ...panel Contact terminals are accessible from front side and isolated from other circuits Following alarms are available AC MCB switch off DC low Replace battery DC or battery MCB switch off DC high Ov...

Page 9: ...et Side entry which is next to MCBs and alarm module is easier to access If bottom entry is preferred oIn models with drawers there are no obstacles between terminals and entry or use cable spiral wra...

Page 10: ...re given at the below MCB In varies according to input and output current Schema 1 Power connections of 24V with multiple DC outputs Schema 2 Power connections of 110V and 24V Schema 3 Alarm module co...

Page 11: ...shown with LEDs Charging mode LED is on and steady if floating or flashing if equalizing charge mode is active AC High Low and DC High Low LEDs are on and steady if over or flashing if under preset va...

Page 12: ...Press SET again to adjust any parameter on the screen After pressing SET cursor will be move onto U parameter 3 Use UP and DOWN buttons to adjust the parameter To cancel press ESC Press SET to move o...

Page 13: ...ter Description Range Step Default Duration Duration of equalizing charge 1 9 hrs 1 hr 1 hr Status Status of equalizing charge mode Active Passive Passive DC Source Mode Parameter Description Range St...

Page 14: ...ge Step Default Annual Battery Maintenance Quantity This parameter determines how many times this method will be applied 1 6 1 4 Maintenance Voltage Minimum battery voltage to stop discharge 21 24 V f...

Page 15: ...10kA C Type Cooling Method Fan forced AF Operating Temperature 20 55 C Relative Humidity 95 RH without condensation Pollution Degree III Alarm Contacts 14 NO mechanical contact 3A 30VDC or 5A 250VAC...

Page 16: ...GEPA Elektronik San ve Tic Ltd ti Zubeyde Hanim Dist Sebzebahceleri St No 93 36 Iskitler 06070 Altindag Ankara Turkey Tel 90 312 341 4104 Fax 90 312 384 0436 www gepaelk com gepa gepaelk com Rev 4 04...

Reviews: