24
4.2.2 Input/Output Settings
The GV-Video Server can connect up to 4 input devices, e.g. sensors. You can set up the
input state to trigger actions by selecting
Open Circuit (N/O)
or
Grounded Circuit (N/C)
.
Furthermore, you can specify the output to be triggered and/or the camera to start
recording once an input is activated. Enabling
Latch Mode
will have a momentary output
alarm.
You can direct a PTZ camera to a preset point upon input trigger:
Set PTZ camera to preset point:
Enable the preset function and select the camera
that represents the PTZ camera.
Input on:
Direct the PTZ camera to a preset point when the input is triggered.
Input off:
Direct the PTZ camera to another preset point when the triggered input is
off.
Duration to set preset after input off x seconds:
Specify the amount of time the
PTZ camera stays in “Input on” preset point before moving to “Input off” preset point.
Figure 4-8
Note:
The input settings only function when you start I/O monitoring manually or by
schedule. Configure the Input and Schedule options in
4.4 Monitoring
.
For related PTZ settings, see
4.2.1 PTZ Settings
.