7.7  In/Out Monitor 

In the left menu, click 

In/Out Monitor

. This page appears.  

 

 

 

 

 

 

 

Input Status: 

Indicates the current status of the 16 inputs, whether it is 

ON

 (triggered) 

or 

OFF

 (no input).

 

 

 

Output Status: 

Indicates the current status of the 16 outputs, whether it is 

ON

 

(triggered) or 

OFF

 (no output). Click the 

ALL ON

 button to force all 16 outputs to be 

triggered. Click the 

ALL OFF

 button to turn off all 16 outputs. Select the individual 

outputs to turn it 

ON

 to force the output to be triggered or turn it 

OFF

 

Click the 

Submit

 button to save the changes, or click the 

Cancel

 button to return the 

changes to its previous state. 

Summary of Contents for GV-I/O BOX 16

Page 1: ...ssigning Addresses to GV I O Box 6 6 3 Extending Transmission over the Distance 7 7 Accessing GV I O Box 16 Ports over Networks 9 7 1 Fixed IP Connection 10 7 2 DHCP Connection 11 7 3 Configuring GV I...

Page 2: ...ed for 30 DC output voltage Up to 16 connections from GeoVision software are allowed to control one GV I O Box for firmware V1 21 or later Optional support for an Ethernet module 2 Compatible Software...

Page 3: ...e 4 switches on the box for dry and wet contact 1 2 3 4 E CE ON A B C D Dry Contact 1 2 3 4 ECE ON A B C D To change the inputs to a different kind of contact push the switch upward To change the inpu...

Page 4: ...ge only H Output DC12V G F E RS 485RX RX 485TX A com A DI 1 USB RX USB TX GV IOBOX 16 Input DI 2 DI 3 DI 4 B com B DI 8 DI 7 DI 6 DI 5 C com C DI 12 DI 11 DI 10 DI 9 D com D DI 16 DI 15 DI 14 DI 13 DO...

Page 5: ...ccessfully 3 Click Exit to close the dialog box and restart the PC To verify the drivers are installed correctly go to Windows Device Manager after restarting the PC Expanding the Ports field you shou...

Page 6: ...TX A com A DI 1 USB RX USB TX GV IOBOX 16 Input DI 2 DI 3 DI 4 B com B DI 8 DI 7 DI 6 DI 5 C com C DI 12 DI 11 DI 10 DI 9 D com D DI 16 DI 15 DI 14 DI 13 DO 4 DO 3 DO 2 DO 1 DO 8 DO 7 DO 6 DO 5 DO 12...

Page 7: ...PC only switch on the Terminal Resistance Switches in the first and last connected pieces of GV I O Box 1 ON 1 ON 1 ON Note If you connect GV IO Box 4 Ports V1 2 as the first device to the PC do not...

Page 8: ...ct multiple pieces of GV I O Box with the PC through separate RS 485 cables switch on Terminal Resistance Switches of the connected piece of GV I O Box at the end of each cable ON ON Terminal Resistan...

Page 9: ...to the GV I O Box 2 When the DHCP server on your network is unavailable or disabled the GV I O Box is accessible by the default IP 192 168 0 100 See 7 1 Fixed IP Connection for details 3 You may also...

Page 10: ...Name field edit the name of the connected GV I O Box 4 Click Disable Type the static IP address information including IP Address Subnet Mask Default Gateway and Domain Name Server 5 Click Submit When...

Page 11: ...GV I O Box GeoVision DDNS Server and DynDNS org To register at GeoVision DDNS Server see the following instructions For details on DynDNS please consult them at www dyndns org GV IOBOX 8 Output Input...

Page 12: ...rd again in the Re type Password field for confirmation 4 In the Word Verification section type the characters or numbers shown in the box For example type i8UCY in the required field Word Verificatio...

Page 13: ...Follow Steps 1 and 2 in 7 1 Fixed IP Connection section The Network Configuration page appears 2 Click Enable and select Send to DDNS 3 Type Host Name User Name and Password that are registered on th...

Page 14: ...value 10000 Mac Address Firmware Version Indicates the MAC address of the network medium and the Ethernet module version of GV I O Box Reboot System Set Default Reboot System Performs a warm boot of...

Page 15: ...gure the input to NC normally closed or NO normally open mode Enable Latch Instead of a constant output of N O or N C this option provides a momentary alarm when triggered Alarm Output Select None for...

Page 16: ...continues to be triggered until the source of the output condition is stopped Toggle Mode N O and N C Output continues to be triggered until a new input trigger ends the output Pulse Mode N O and N C...

Page 17: ...ates the current status of the 16 outputs whether it is ON triggered or OFF no output Click the ALL ON button to force all 16 outputs to be triggered Click the ALL OFF button to turn off all 16 output...

Page 18: ...d button This update procedure may take 60 seconds to complete 4 When Update is complete a dialog box appears and asks you to reboot the system 5 Click OK GV I O Box starts the Reboot operation Note 1...

Page 19: ...OS 64 bit Windows 7 8 8 1 10 Server 2008 R2 Server 2012 R2 Input 16 Dry Contact Input Input Signal Wet Contact 9 30V AC DC Relay Output 16 Relay Status Normal Open USB Connection 30V DC 3A RS 485 Con...

Reviews: