3.1.2 Setting GV-FR Panel to be a Door
Once GV-AS Controller has been connected to GV-ASManager, you then need to connect
GV-FR Panel to GV-AS Controller. To do so, follow the steps below.
Note:
The following procedures are only applied to GV-FR Panel V1.2.0 or later.
1. On the menu bar of GV-ASManager, click
Setup
and select
Devices
.
2. Double-click the controller that GV-FR Panel to be connected to and select a
Door
. This
dialog box appears.
3. Select
GV-FR Panel
from the
Entrance
and/or
Ext
dropdown list, in accordance to your
installation site.
4. Type the
IP address
,
Port number
,
Account ID
and
Password
of the GV-FR Panel.
5. Click
OK
. The GV-FR Panel is connected to the controller and GV-ASManager is also
connected with GV-FR Panel.
To verify the connection on
GV-FR Panel
:
6. On the GV-FWC / Controller Setting page (
Notify Settings
>
GV-FWC/Controller
), you
should find an entry, for example,
[ASManager] Door 4-FR (In)
, written back from GV-
ASManager to indicate which controller IP and which door is connected to.