Total Station Manual
38
3.3 Measurement
After all settings have been finished, you can start to measure. There are 3 pages
to display the result of measurement, including all measurement data and you can
press [PAGE] to view.
Steps
Key
Display
ƻ
1 Input the name of point
and instrument height.Move
the cursor to the next edit text
after entering each item. You
can
enter
Code
when
necessary.
[ENT]
+
[ENT]
ƻ
2 Aim at the center of prism,
press
[F1](ALL)
or
[F2](DIST)+[F3](REC)
to
start to measure and record the
measurement
data.
The
measurement data including
angle data, distance data and
coordinatedata.You can press
[PAGE] to view.
[F1]
or
[F2]
+
[F3]
ƻ
3 After finishing measuring
a point, program makes the
number
of
point
add
1
automatically, aim
at
the
center of prism and repeat the
above steps to start next point
measurement.