Total Station Manual
17
completely.
z
Charge the battery once a month no matter if it is used to prolong its longevity.
4. Reflecting prism
When using a prism mode for measuring distance, reflection prism should be
placed where the target is. A reflecting prism group includes one or three prisms that
can connect prism group placed at the base of the tripod with the dock connector or by
placing them in the stem directly. Prism group may need to be configured by users
based on target.
5. Load or unload the base
z
Load
Put the three fixed feet in the corresponding bases, make the instrument in a
triangular base, clockwise lock the button by 180
e
to lock the base, and then fix
screw with a screwdriver to screw it out at a fixed lock knob.
ƽ
Unload
If necessary, the triangle base can be removed from the instrument (including the
same base of reflection prism base connector) by loosening the lock knob base fixed
screw with a screwdriver, and anticlockwise locking button about 180
e
, then
separate the instrument from base.
6. Adjust telescope objective and aiming target
Aiming method (reference)
ķ
Rotate the telescope and point it to the bright sky and focus reticule clearly (by
rotating eyepiece in own direction and focusing reticule slowly ).
ĸ
Aim at the target with the crosswire in optical sight , and keep an appropriate
distance when aiming ( about 200mm).
Ĺ
Use telescope focus screw to make target clear.
It means that focus or eyepiece diopter is not adjusted adjusted when there is a
parallax with eye moving up and down, thus focus carefully and adjust eyepiece to
reduce parallax.
7. Input Mode
Total station keybord includes alpha/digit keys.User can input letters and numbers
directly.
z
Input box:
Each digit key defines 3 letters and 1 number. Depends on the properties of input
box, input process varies.