Page 20/32
© Geobrugg Gruppe, CH-8590 Romanshorn, Switzerland
Maintenance manual RXE, GBE / 09
Release the cable pulley device so that the tensile force is transferred to the new rope.
Detach the cable pulley device.
8.4
Replacing U-brakes
Fit the clips of the cable pulley device to the rope of the U-brake
01
and the fastening of the U-brake
(e.g. rope anchor)
02
.
Carry out the remaining steps as described in section 8.28.1:
Actuate the cable pulley device until the entire tensile force is on the cable pulley device.
Remove the shackle of the U-brake from the loop of the rope.
Replace the U-brake and return the shackle to the loop.
Release the cable pulley device so that the tensile force is transferred to the U-brake rope.
Detach the cable pulley device.
01
02