![Geobrugg GBE-500A-R Maintenance Manual Download Page 17](http://html.mh-extra.com/html/geobrugg/gbe-500a-r/gbe-500a-r_maintenance-manual_2214452017.webp)
Page 17/32
© Geobrugg Gruppe, CH-8590 Romanshorn, Switzerland
Maintenance manual RXE, GBE / 09
Wire rope di-
ameter
[mm]
Size
of the
wire rope clip
Required
amount of
wire rope clips
Required
tightening
torque lubri-
cated
[Nm]
Required
tightening
torque
unlubricated
[Nm]
Wrench
size
[mm]
3 - 4
1/8‘‘
2
4
8
10
6 - 7
1/4‘‘
2
10
25
15
8
5/16“
3
20
50
18
9 - 10
3/8“
3
30
75
19
11 - 12
7/16“
3
40
110
22
14 - 15
9/16“
3
50
150
24
16
5/8“
3
90
170
24
18 - 20
3/4‘‘
4
90
180
27
22
7/8“
4
150
330
32
22 GEOBINEX
7/8“
5
150
330
32
A visible contusion of the wire ropes positively indicates that the wire rope clips have been tightened to the
required tightening torque.
Undamaged wire rope clips could be reused. Especially the threads and clamping jaw have to be
checked.
Wire rope clips always have to be installed and used with the required tensioning torque.
After the first load application the tightening torque has to be checked and if
not fulfilled adjusted to the required value.