16
Pressure Maximum
To reset and redefine “9” for the pressure
bar graph, use this calibration menu. Do
NOT adjust this setting unless you are
sure adjustments are necessary.
Adjust the pressure of the machine
so there is extremely heavy pressure
when clamping and locking the press.
Press either Arrow Key. The press now
considers this pressure as “9” on the
Pressure Bar Graph Display.
Press PRG to move to the next menu item.
Temperature Drop Sense
The press can be set to alarm if the
temperature drops a certain range below
the set temperature. This is useful to
warn the operator if the press is too
far out of temperature range during
excessive use.
After entering the user menus (see top of
page 14), Press PRG until DRP displays.
Use the arrow keys to set it to OFF (default), or 10, 20, 30, etc.
If the current temperature drops below the set temperature by that many
degrees, and alarm will sound. Press TEMP to silence the alarm.
Press PRG to move to the next menu item.