background image

5

   Care and cleaning

   Please handle measuring instruments with care.
   Clean with soft cloth only after any use. If neces-

 

   sary damp cloth with some water. 
   If instrument is wet clean and dry it carefully. Pack

 

   it up only if it is perfectly dry.
   Transport in original container / case only.

Curatire si Intretinere

   

Verificare precizie

 

 

 

 

 

 

 

 
 

 

 
 

   Accuracy check

   Set up instrument in the middle of two walls which 

 

   are about 5 m apart. Press buttons H and V1. Mark 

 

   visible laser cross on one wall. Turn unit to oppo-

 

   site wall and mark laser cross. 

   Repeat measurements with distance of about 0.6 m 

 

   to one wall and about 4.4 m to second wall. Devia-

 

   tion between two measurements taken from the 

 

   centre and two measurements taken at 0.6 m and  

 

   4.4 m must not exceed 3 mm.

   Testing accuracy of horizontal line (end to end)

   Set up instrument about 5 m from a wall. Press 

 

   buttons H and V1. Mark laser cross on the wall. 

 

   Turn instrument until the laser cross has moved 

 

   about 2.5 m to the left side and check if horizontal 

 

   line is within ± 2 mm of laser cross marked on 

 

   wall. Repeat measurement by turning instrument to 

 

   the right side

   Testing accuracy of vertical line (end to end)

   Set up instrument about 5 m from a wall. Fix a 

 

   plumb line of 2.5 m length to the wall, using a 

 

   plumb bob. Press button V1 and bring laser line 

 

   into  coincidence with the plumb line. Deviation 

 

   between laser line and plummet cord from top to 

 

   bottom must not exceed ± 1.5 mm.

Configura

þ

i instrumentul în mijlocul a dou

ã

 

ziduri care sunt de aproximativ 5 m distanta. 
Ap

ã

sa

þ

i butoanele H 

þ

i V1. Marcati crucea cu 

laser vizibil pe un perete. Roti

þ

i unitatea la 

peretele opus 

þ

i marcati crucea cu laser.

Se repet

ã

 m

ã

sur

ã

torile cu distanta de 

aproximativ 0,6 m de un perete 

þ

i de 

aproximativ 4,4 m fa

þ

ã

 de al doilea zid. 

Aabaterea între dou

ã

 m

ã

sur

ã

tori luate din 

centru 

þ

i dou

ã

 m

ã

sur

ã

tori luate la 0,6 m 

þ

i 4,4 

m nu trebuie s

ã

 dep

ã

þ

easc

ã

 3 mm.

Precizie Testarea linie orizontal

ã

 (cap la cap)

Configura

þ

i instrumentul la circa 5 m de un 

perete. Ap

ã

sa

þ

i butoanele H 

þ

i V1. Marcati 

crucea laser de pe perete. Roti

þ

i instrumentul 

pân

ã

 când crucea cu laser s-a mutat 

aproximativ 2,5 m, spre partea stâng

ã

 

þ

verifica

þ

i dac

ã

 Linia orizontal

ã

 este în limitele 

de ± 2 mm fata de crucea laser marcat

ã

 pe 

peretele. Repetati m

ã

surarea intorcand 

instrumentul catre partea dreapt

ã

Testarea preciziei linie vertical

ã

 (cap la cap)

Configura

þ

i instrumentul la circa 5 m de un 

perete. Asezati paralel linia vertical

ã

 fata de 

2,5 m lungime de perete, folosind un fir cu 
Plumb. Ap

ã

sa

þ

i butonul V1 

þ

i aduceti linia laser 

în coinciden

þ

ã

 cu firul cu plumb. Abaterea între 

linia de centrare laser 

þ

i cablul de sus pana jos 

nu trebuie s

ã

 dep

ã

þ

easc

ã

 ± 1,5 mm.

-V

ã

 rug

ã

m s

ã

 manuiti instrumente de masurare cu grij

ã

-Cur

ã

tati cu o cârp

ã

 moale dup

ã

 orice utilizare. Dac

ã

 

este necesar , folositi o cârp

ã

 umed

ã

 cu pu

þ

in

ã

 ap

ã

-În cazul în care instrumentul este umed curatati-l 

þ

uscati-l cu aten

þ

ie. 

-Impachetati-l numai dac

ã

 acesta este perfect uscat. 

Transportul, în ambalajul original / numai el.

Summary of Contents for FL 40-3Liner

Page 1: ...Manual Utilizare Users manual Linii laser incrucisate automate Fully Automatic Laser Cross Level FL 40 3Liner...

Page 2: ...r suport perete trepied set baterii tinta magnetica ochelari intensificare raza laser cutie captusita de transport instructiuni Optional Receptor FR 55 M KIT CONSISTS OF Laser Cross Level FL 40 3Liner...

Page 3: ...tripod or floor to ceiling pillar 5 8 thread b to a wall there are three screw eyes on the mount through which unit can be fixed Switch on ON OFF Turn the base 3 in position ON position OFF shut off...

Page 4: ...s by use of the receiver More de tailed information you will find in users manual of FR 55 M ref no 500520 4 Note During transport base no 3 must be set to position LOCK Disregard may lead to damage o...

Page 5: ...ord from top to bottom must not exceed 1 5 mm Configura i instrumentul n mijlocul a dou ziduri care sunt de aproximativ 5 m distanta Ap sa i butoanele H i V1 Marcati crucea cu laser vizibil pe un pere...

Page 6: ...r beam in order to carry out the following measuring tasks depen ding on instrument Setting up heights horizontal and vertical planes right angles and plumbing points Instrumentul emite un laser fasci...

Page 7: ...s product if it has been misused abused or altered Without limiting the foregoing leakage of the battery bending or dropping the unit are presumed to be defects resulting from misuse or abuse 7 Laser...

Page 8: ...ge caused by wrong movement or action due to connec ting with other products 10 2007 Utilizatorul acestui produs este de a teptat s urmeze instruc iunile date n manualul de utilizare De i toate instru...

Reviews: