USE OF THE LASER

(only model FET 402K-L)

With the built-in laser beam the target can be aimed at and marked. By focussing the laser dot can be 

adjusted. Such, the marking of the target can be acomplished by one person only.

The laser beam is pulsed and can therefore be used together with any geo-FENNEL receiver for rota-

ting lasers. Thus, FET 402K-L can be applied for any task that would require the use of a rotating laser.

Power on the laser beam with the laser key.Turn the laser key to adjust the brightness of the laser 

beam.

The smallest diameter of the laser dot will be achieved if the laser beam is focussed.

By means of the laser beam all measuring tasks can be acomplished and will be visualized to the user.

INITIAL SETTING

The instrument supplies multi-functions for your selection to meet the different requirements of 

measuring configuration.

ITEM

1

2

3

4

5

6

Change between

10“ and 20“

Confirm every 90°

by signal tone

Change between DEG

(degree), GON, MIL

Set interval for auto-

matic shut-off

Set „o“ point of 

vertical angle

Set incline correction

function

Minimum

reading

Quadrant

signal tone

Unit of angle

measurement

Auto shutt-off

Measuring mode

for vertical angle

Automatic

compensation

PRAMETER SET

-

TING

Setting 0

1“

Setting 0

off

Setting 0/DEG 

 Setting 1/GON

Setting 0/Off

Setting 1/10 min.

Setting O

Setting 1

Setting 2

Setting 0

Off

Setting 1

5“

Setting 1

on

Setting 2/MIL 

Setting 2/20 min.

Setting 3/30 min.

Vertical angle

(0 in horizontal)

Zenith angle

(0 in zenith)

Height angle +/-

(0 in horizontal)

Setting 1

On

Setting 

10“

Summary of Contents for FET 402K-L

Page 1: ...USER MANUAL www geo fennel com EN FET 405K FET 420K FET 402K L...

Page 2: ...uarantees a longtime and reliable operation geo FENNEL Precision by tradition SUPPLIED WITH A Elektronic Theodolite FET 405K FET 420K FET 402K L Battery and charger Container User manual FEATURES 2 la...

Page 3: ...Measuring units 400 gon 360 mil Optical plummet 3 x Focusing range 0 5 Plate level 30 2 mm Circular level 8 2 mm Operating time power supply 35 h NiMH 40 h Alkaline Temperature range 20 C up to 50 C D...

Page 4: ...f the charger into the charging socket of the battery box RED LIGHT at the charger indicates that the batteries are being charged GREEN LIGHT at charger indicates that the batteries have been fully ch...

Page 5: ...rew 6 Horizontal clamp knob 7 Display 8 Instrument center mark 9 Optical plummet 10 Plummet eyepiece 11 Circle vial 12 Foot screw NOMENCLATURE 1 1 Handle 2 Objective lens 3 Optical sight 4 Laser butto...

Page 6: ...lashing digit DISPLAY INDICATION 1 Ht Total value of repeated measure ments 2 V Vertical angle 3 Number of repeated measure ments 4 AVG Average of repeated measure ments 5 HR Right horizontal angle 6...

Page 7: ...ilt in optical plummet Focus the target with the eypiece of the optical plummet and focus the ground point with the focussing ring POWER ON THE INSTRUMENT Press the POWER button for 1 sec The manufact...

Page 8: ...NING INCREMENT Aim at target A using the crosshair of the telescope Press the R L key transform the horizontal angle mode HR into the mode HL Measuring with mode HL The R L key is of no effect to the...

Page 9: ...m at the second target B 5 Press the HOLD key to hold the horizontal angle and store in the instrument 6 Turn the horizontal tangent knob to aim at target A again Press the R L key to release the angl...

Page 10: ...the display and crosshair can be illuminated Power on the illumination Press the button FUNC F will be displayed press the button FUNC again the illumination is now powered on Power off the illuminati...

Page 11: ...can be acomplished and will be visualized to the user INITIAL SETTING The instrument supplies multi functions for your selection to meet the different requirements of measuring configuration ITEM 1 2...

Page 12: ...ain The collimate rotation is too fast Press the 0SET key to set 0 If E00 is shown again the instrument needs to be repaired The telescope turning is too fast Press the V key to set 0 for the vertical...

Page 13: ...ITY EMC It cannot be completely excluded that this instrument will disturb other instruments e g navigation sys tems will be disturbed by other instruments e g intensive electromagnetic radiation near...

Page 14: ...authority and the appoint ment of a laser protection official Do not operate the laser without first reading and understanding all the safety and technical data in the user manual The user manual mus...