![Genther MPAII Installation And Operation Manual Download Page 29](http://html1.mh-extra.com/html/genther/mpaii/mpaii_installation-and-operation-manual_2213784029.webp)
MPAII Installation and Operations Manual Page 25
Technical or Setup Assistance
Telephone: 800.945.7730 (USA) or 801.975.7200 (worldwide) • Worldwide Web @ http://www.gentner.com
SPEAKER:
Spring-loaded wire clamps
PA INPUT:
3-pin female XLR; +4dBm nominal, adjustable;
20Kohms, balanced; bridging
PA OUTPUT:
3-pin male XLR; +4dBm nominal, 600ohms, balanced
Power Requirements
100/120/220/240Vac switchable; 50/60Hz
Audio Performance: Mic Mixer
Frequency Response
20Hz to 20kHz +1dB
Signal-to-Noise Ratio
>60dB ref., -55dBu input, +4dBm output
Total Harmonic Distortion
<.1 percent
Audio Performance: Power Amp
Frequency Response
+/- 1dB, 50Hz–20kHz; +/-3dB, 20Hz–20kHz
Signal-to-Noise Ratio
>80dB ref., +4dBm input, 15W into 8ohms output
Total Harmonic Distortion
<0.1 percent
Power Amp Output
2x15W into 8ohms
Operating Temperature
32–110° F
Specifications are subject to change without notice.