midipc
Set Preset Range
This item is simply for convenience. The preset values will be setup on a PC and
downloaded to the MIDI Patch Changer keypad using a System Exclusive dump.
The Preset Range adjustment just allows you to visualize your presets as either
0-99 or 1-100.
You can modify the value using the Up and Down arrow keys or the 0 and 1
keys. Press Enter once you have made your selection.
System Exclusive Mfg ID
The System Exclusive Manufacturing ID is used to uniquely identify a specific
MIDI device while doing Sys Ex dumps from a host PC. You can adjust the Sys
Ex ID of the MIDI Patch Changer keypad so that it does not conflict with any of
your other MIDI gear.
The displayed value is in hexadecimal (since that the is most common format for
these IDs). You modify the value using the Up and Down arrow keys. Press
Enter once you have made your selection. Remember to use the value you set
when doing System Exclusive communications with the keypad.
NOTE: The editor/librarian does not yet support alternate Mfg IDs.
MIDI Monitor
You can set the MIDI Monitor ON or OFF. This is a very simple one-line display
showing the last MIDI command received. When enabled, the monitor data is
overlaid live on the MIDI Patch Changer LCD regardless of mode or menu. Press
any keypad key to temporarily regain control of the LCD. This setting is not
retained in non-volatile memory.