8
CONTROL FUNCTIONS
CONTROL PANEL FEATURES GM7250iEDC
①
120-Volt, 20-Amp Outlet:
The outlet is capable of
carrying a maximum of 20 amps.
②
USB Duplex:
5V DC that come in 1 amps and 2.1
amps.
③
Reset Breaker:
If the inverter is overloaded, the
reset breaker will trip. The engine will continue to run,
but there will be no output from the inverter. Unplug the
devices and reduce the load. Push in the reset breaker
to reset it.
④
Low Idle:
When turned to the ON position, the
engine will sense the load needed and run at a slower
RPM to save fuel.
⑤
Ground Terminal:
The ground terminal is used to
externally ground the inverter.
⑥
Fuel Source:
GAS/LPG valve that changes the fuel
into the engine.
⑦
AC Breaker:
If the inverter is overloaded, the reset
breaker will trip to block current.
⑧
Main Switch:
Manage battery power and shutdown.
⑨
120/240-Volt, 50-Amp Outlet:
The outlet is capable
of carrying a maximum of 50 amps.
⑩
CO Alarm:
Flashing red light: dangerous levels of
carbon monoxide gas have built up leave immediately
until area has aired out. Move generator to well-
ventilated area before operation. Flashing yellow light:
carbon monoxide sensor malfunction. Sensor needs
service.
⑪
One Push Start:
Press this button, the engine can
start and stop.
⑫
Parallel Connectors:
To increase AC power output,
the connector sockets are used to connect the two
same type generator with special paralleling cords.
The connector sockets is only used to the
communication between the inverters, they can not
used for AC power output. The special paralleling
cords shall be purchase separately, and they shall be
approved by certification body.
⑬
LPG Hose Connection Port:
When LPG gas is
used, install the dedicated LPG hose on the connection
port.
⑭
Voltage Selector:
Switch between 120V and 240V
voltage as required.
⑮
ATS:
ATS control box connection port
.
11
10
12
13
14
15