background image

15

ENGLISH

LOGIC "A"

PULSES

GATE STATUS

OPEN-A

OP/CLOS. SAFETY DEVICE

CLOSING SAFETY DEVICES

OPENING SAFETY DEVICES

STOP

Opens leaves and closes them after

pause time (1)

Opens the free leaf and closes after

pause time (1)

OPEN on PAUSE

Reloads pause time (1)

OPEN-B

Reloads pause time (1)

No effect

Freezes pause until release (2) (OPEN disabled)

CLOSED

No effect

No effect (OPEN disabled)

AT CLOSING

Re-opens  the  leaves  immediately (1)

Re-opens the leaf immediately (1)

No effect (saves OPEN)

see paragraph 5.2.

AT OPENING

No effect (1)

Reverses  at closing

No effect

Locks and, on release, continues opening

Stops operation

LOCKED

Closes the leaf/leaves

No effect (OPEN disabled)

No

 ef

fe

ct

No effect (OPEN disabled)

No effect (OPEN disabled)

Table 3/a

Locks and, on release, reverses at opening

Table 3/b

LOGIC "S"

PULSES

CLOSED

GATE STATUS

OPEN-A

OPEN-B

STOP

OPENING SAFETY DEVICES

CLOSING SAFETY DEVICES

OP/CLOS. SAFETY DEVICE

Opens leaves and closes them after pause

time

Opens the  free leaf and closes after

pause time

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN on PAUSE

Stops operation

Stops operation

No effect

Closes after 5" (OPEN disabled)

AT CLOSING

Re-opens  the  leaves  immediately

Re-opens the leaf immediately

No effect (saves OPEN)

se

pa

ra

gr

aph 5.2.

Locks and, on release, reverses at opening

AT OPENING

Stops operation

Stops operation

Stops operation

Reverses  at closing

No effect

Locks and, on release, continues opening

LOCKED

Closes the leaf/leaves

No effect (OPEN disabled)

No

 ef

fe

ct

No effect (OPEN disabled)

LOGIC "E"

PULSES

Table  3/c

GATE STATUS

OPEN-A

OPEN-B

STOP

OPENING SAFETY DEVICES

CLOSING SAFETY DEVICES

OP/CLOS. SAFETY DEVICE

CLOSED

Opens the leaves

Opens the free leaf

No effect (OPEN disabled)

No effect

No effect (OPEN disabled)

OPEN

Re-closes the leaves immediately

Re-closes the leaf immediately

No effect (OPEN disabled)

No effect

AT CLOSING

Re-opens  the  leaves  immediately

Re-opens the 

leaf immediately (1)

No effect (saves OPEN)

see paragraph 5.2.

Locks and, on release, reverses at opening

AT OPENING

Stops operation

Reverses  at closing

No effect

Locks and, on release, continues opening

Stops operation

LOCKED

Closes the leaf/leaves

(with  CLOSING SAFETY DEVICES active, opens at 2nd pulse)

No effect (OPEN disabled)

No

 ef

fe

ct

No effect (OPEN disabled)

Summary of Contents for JA574

Page 1: ...UR PORTAILS BATTANTS CENTRAL DE MANDO CON MICROPROCESADOR PARA PORTONES DE TIPO BATIENTE MIKROPROZESSOR STEUEREINHEIT F R FL GELTORE ISTRUZIONI PER L USO NORME DI INSTALLAZIONE USE AND INSTALLATION IN...

Page 2: ...inflammablegasorfumesisaseriousdangertosafety 8 ThemechanicalpartsmustconformtotheprovisionsofStandardsEN12604 andEN12605 For non EU countries to obtain an adequate level of safety the Standards ment...

Page 3: ...OW VOLTAGE TERMINAL BOARD J2 RAPID CONNECTOR 5 PINS J3 230 VAC POWER SUPPLY TERMINAL BOARD J4 MOTORS AND FLASHING LAMP CONNECTION TERMINAL BOARD F1 MOTORS AND TRANSFORMER PRIMARY WINDING FUSE F 5A F2...

Page 4: ...ng photocells and a pair of opening closing photocells recommended lay out 1 2 5 4 3 1 2 RX CL TX CL 1 2 5 4 3 1 2 RX OP CL TX OP CL 9 10 11 12 13 14 15 16 17 18 19 OPEN A B STP CL OP FSW 24V TX FSW F...

Page 5: ...CL OP FSW 24V TX FSW 1 2 5 4 3 1 2 RX TX Fig 9 Connection of 1 pair of closing photocells Fig 12 Fig 13 Connection of 2 N C contacts in series e g Photocells Stop Connection of 2 N O contacts in paral...

Page 6: ...ng safety devices operate when the gate is open they preventtheleafclosingmovement NB If no closing safety devices are connected jumper connect terminals CL and TX FSW fig 7 OPFSW Terminal13plusanegat...

Page 7: ...AX OFF OFF OFF 1 2 3 4 5 6 7 8 9 10 11 12 1 MIN 2 3 4 SW4 ON OFF ON OFF SW5 ON ON OFF OFF 5 6 ON ON OFF ON SW6 ON ON ON ON OFF OFF 7 OFF ON OFF 8 MAX OFF OFF OFF E SW7 ON SW8 ON A A ON ON OFF ON SW9 O...

Page 8: ...orrectly Most important of all check if the force is adequately adjusted and if the safety devices are operating correctly 6 START UP 6 1 LED CHECK The table below shows the status of the LEDs in rela...

Page 9: ...ffect OPEN disabled OPEN on PAUSE Stops operation Stops operation No effect Closes after 5 OPEN disabled AT CLOSING Re opens the leaves immediately Re opens the leaf immediately No effect saves OPEN s...

Page 10: ...PEN A disabled No effect OPEN B disabled No effect OPEN A disabled OP CLOS SAFETY DEVICE CLOSING SAFETY DEVICES OPENING SAFETY DEVICES STOP OPEN B Stops operation OPEN A B disabled No effect Opens the...

Page 11: ...a evitar que la automaci n pueda ser accionada involuntariamente HINWEISE F R DEN INSTALLATIONSTECHNIKER ALLGEMEINE SICHERHEITSVORSCHRIFTEN 1 ACHTUNG Um die Sicherheit von Personen zu gew hrleisten so...

Page 12: ...ti essenziali di sicurezza delle seguenti direttive 73 23 CEE e successiva modifica 93 68 CEE 89 336 CEE e successiva modifica 92 31 CEE e 93 68 CEE Grassobbio 01 06 2005 L Amministratore Delegato D G...

Reviews: