background image

GE-VX INSTALLATION  

GE-VX 

Section B-8 

Electrical Cables 

-

 

All electrical cables must be installed according to local wiring codes. 

-

 

All cable shields must be connected to the main control only. Do not connect it to the 
GE-VX.  The  shield  is  needed  to  protect  the  modules  against  any  electromagnetic 
interference generated by lightning or nearby operating machinery. 

-

 

Never use the shield as a conductor. 

-

 

Use  separate  conduits  for  the  low  voltage  cables  (communication)  and  the  high 
voltage cables. There must be at least 1 foot (30 cm) between low-voltage and high-
voltage conduits. 

-

 

If a low voltage cable has to cross over a high voltage cable, make this crossing at 
90°. 

-

 

All cable connections must be soldered or done with approved sealed connectors. 

-

 

See main control manual for cable length. 

-

 

It is prohibited to use overhead cables outside the building. 

-

 

Use the wire connector to connect the ground wire to the ground of the electrical 
installation. 

Electrical Power  

-

 

Protection  from  electrical  surges  should  be  included  in  the  planning  of  each 
installation. 

-

 

Every module should have a separate breaker to avoid possible problem. 

-

 

This module requires the same phase and voltage as the board to which it is 
connected to (GE Control, Var Board (X1204), etc.). 

 

www.monitrol.com

Summary of Contents for GE-V1

Page 1: ...GE V1 V2 Installation User s Guide ATTENTION ELECTRICIAN SEE WIRING DETAILS ON PAGES A 3 A 4 AND A 5 ADDITIONAL INFORMATION IN SECTION B WIRING DIAGRAM INSTALLATION INDEX WARRANTY www monitrol com...

Page 2: ...nst line voltage surges it is recommended that surge and noise suppression devices be installed at the electrical distribution panel These devices are available from most electrical supply distributor...

Page 3: ...V2 1 module on one port 1243 B GE Vx 1 2 OUT 1 115 230V INPUT 1 2 OUT 2 115 230V L2 N L2 N L1 L1 WIRING DIAGRAM GE V1 AND GE V2 1 module on one port WIRING DIAGRAM GE VX 07 12 09 CONFIGURATION WIR REV...

Page 4: ...OUT 1 115 230V INPUT 1 2 OUT 2 115 230V L2 N L2 N L1 L1 WIRING DIAGRAM GE V1 AND GE V2 2 modules on one port WIRING DIAGRAM GE VX 07 12 09 CONFIGURATION WIR REV 0 5 5 4 6 7 1243 B GE Vx 1 2 OUT 1 115...

Page 5: ...R POTENTIOMETER WIRES AT LEAST 12 INCHES 30cm AWAY FROM HIGH VOLTAGE WIRES 120 230VAC 24VDC ALWAYS CROSS HIGH AND LOW VOLTAGE WIRES AT A 90 DEGREE ANGLE THE CURRENT SHALL NOT EXCEED 12 5A AT EACH OUTP...

Page 6: ...INSTALLATION GE V1 and GE V2 SECTION B www monitrol com...

Page 7: ...the electrician notes for the capacitance selection 4 screws to hang the unit onto the wall Screwdrivers Soldering iron kit or approved sealed connectors General installation guidelines GE V1 or GE V2...

Page 8: ...etween low voltage and high voltage conduits If a low voltage cable has to cross over a high voltage cable make this crossing at 90 All cable connections must be soldered or done with approved sealed...

Page 9: ...four screws provided with the brackets Then mount the enclosure on the wall by inserting screws through the brackets adjustment slots into the wall Make sure to position the enclosure so that all wir...

Page 10: ...GE VX INSTALLATION GE VX Section B 10 Layout Board FIGURE NO 2 GE V2 and GE V1 Electronic module Board 15A SLO BLO 15A SLO BLO 1243 B 1 1 2 2 OUT 1 115 230V OUT 2 115 230V INPUT www monitrol com...

Page 11: ...on port terminal block with the module negative communication port terminal block Typical Thermostat Backup Wiring If the GE VX Module fails the backup thermostats will activate the dedicated fan as s...

Page 12: ...re 32 F to 122 F 0 C to 50 C Humidity 90 maximum Non condensing Weight 2 lb 0 9Kg Size 12 1 4 x 11 x 4 3 4 32 cm x 28 8 cm x 11 5 cm Norms CSA NRTL C Protection index IP 54 dust and splashing water Wa...

Page 13: ...GE VX INSTALLATION GE VX Section B 13 www monitrol com...

Page 14: ...INDEX WARRANTY GE V1 and GE V2 SECTION C www monitrol com...

Page 15: ...rical Power 8 Mounting 9 Layout Board 10 Connection Procedure 11 Detailed Wiring Diagrams 11 Communication Port Connection 11 Typical Thermostat Backup Wiring 11 Powering Up Procedure 12 Verify all Co...

Page 16: ...of God flood fire hail or any other natural disaster Any unauthorized work modification or repair on this product automatically voids the warranty and disclaims the manufacturer from all responsibilit...

Page 17: ...GE V1 GE V2 VER 1 3 March 21 2022 www monitrol com...

Reviews: