Genius GE-V1 Installation & User Manual Download Page 16

GE-VX INDEX / WARRANTY 

GE-VX 

Section C-16 

Limited Warranty 

 
The  manufactured  equipment  and  supplied  components  have  gone  through  rigorous 

inspection  to  assure  optimal  quality  of  product  and  reliability.  Individual  controls  are 

factory  tested  under  load,  however  the  possibility  of  equipment  failure  and/or 

malfunction may still exist. 

 

For service, contact your local retailer or supplier. The warranty period shall be for two 

years from manufacturing date. Proof of purchase is required for warranty validation. 

 

In  all  cases,  the  warranty  shall  apply  only  to  defects  in  workmanship  and  specifically 

exclude  any  damage  caused  by  over-voltage,  short  circuit,  misuse,  acts  of  vandalism, 

lightning,  fortuitous  events,  acts  of  God,  flood,  fire,  hail  or  any  other  natural  disaster. 

Any  unauthorized  work,  modification  or  repair  on  this  product  automatically  voids  the 

warranty and disclaims the manufacturer from all responsibility. 

 

The  manufacturer  assumes  only  those  obligations  set  forth  herein,  excluding  all  other 

warranties or obligations. This warranty stipulates that in all cases the manufacturer shall 

be liable only for the supply of replacement parts or goods and shall not be liable for any 

personal injury, damages, loss of profits, interrupted operations, fines for infringement of 

the law or damages to the production of the PURCHASER and the PURCHASER shall 

take up the defense and hold the manufacturer faultless regarding any legal or extra legal 

proceedings, notice, or claim by the customer or by a third party, and regarding any legal 

and extra legal expenses and fees brought forward on by such damages.

 

www.monitrol.com

Summary of Contents for GE-V1

Page 1: ...GE V1 V2 Installation User s Guide ATTENTION ELECTRICIAN SEE WIRING DETAILS ON PAGES A 3 A 4 AND A 5 ADDITIONAL INFORMATION IN SECTION B WIRING DIAGRAM INSTALLATION INDEX WARRANTY www monitrol com...

Page 2: ...nst line voltage surges it is recommended that surge and noise suppression devices be installed at the electrical distribution panel These devices are available from most electrical supply distributor...

Page 3: ...V2 1 module on one port 1243 B GE Vx 1 2 OUT 1 115 230V INPUT 1 2 OUT 2 115 230V L2 N L2 N L1 L1 WIRING DIAGRAM GE V1 AND GE V2 1 module on one port WIRING DIAGRAM GE VX 07 12 09 CONFIGURATION WIR REV...

Page 4: ...OUT 1 115 230V INPUT 1 2 OUT 2 115 230V L2 N L2 N L1 L1 WIRING DIAGRAM GE V1 AND GE V2 2 modules on one port WIRING DIAGRAM GE VX 07 12 09 CONFIGURATION WIR REV 0 5 5 4 6 7 1243 B GE Vx 1 2 OUT 1 115...

Page 5: ...R POTENTIOMETER WIRES AT LEAST 12 INCHES 30cm AWAY FROM HIGH VOLTAGE WIRES 120 230VAC 24VDC ALWAYS CROSS HIGH AND LOW VOLTAGE WIRES AT A 90 DEGREE ANGLE THE CURRENT SHALL NOT EXCEED 12 5A AT EACH OUTP...

Page 6: ...INSTALLATION GE V1 and GE V2 SECTION B www monitrol com...

Page 7: ...the electrician notes for the capacitance selection 4 screws to hang the unit onto the wall Screwdrivers Soldering iron kit or approved sealed connectors General installation guidelines GE V1 or GE V2...

Page 8: ...etween low voltage and high voltage conduits If a low voltage cable has to cross over a high voltage cable make this crossing at 90 All cable connections must be soldered or done with approved sealed...

Page 9: ...four screws provided with the brackets Then mount the enclosure on the wall by inserting screws through the brackets adjustment slots into the wall Make sure to position the enclosure so that all wir...

Page 10: ...GE VX INSTALLATION GE VX Section B 10 Layout Board FIGURE NO 2 GE V2 and GE V1 Electronic module Board 15A SLO BLO 15A SLO BLO 1243 B 1 1 2 2 OUT 1 115 230V OUT 2 115 230V INPUT www monitrol com...

Page 11: ...on port terminal block with the module negative communication port terminal block Typical Thermostat Backup Wiring If the GE VX Module fails the backup thermostats will activate the dedicated fan as s...

Page 12: ...re 32 F to 122 F 0 C to 50 C Humidity 90 maximum Non condensing Weight 2 lb 0 9Kg Size 12 1 4 x 11 x 4 3 4 32 cm x 28 8 cm x 11 5 cm Norms CSA NRTL C Protection index IP 54 dust and splashing water Wa...

Page 13: ...GE VX INSTALLATION GE VX Section B 13 www monitrol com...

Page 14: ...INDEX WARRANTY GE V1 and GE V2 SECTION C www monitrol com...

Page 15: ...rical Power 8 Mounting 9 Layout Board 10 Connection Procedure 11 Detailed Wiring Diagrams 11 Communication Port Connection 11 Typical Thermostat Backup Wiring 11 Powering Up Procedure 12 Verify all Co...

Page 16: ...of God flood fire hail or any other natural disaster Any unauthorized work modification or repair on this product automatically voids the warranty and disclaims the manufacturer from all responsibilit...

Page 17: ...GE V1 GE V2 VER 1 3 March 21 2022 www monitrol com...

Reviews: