13
G
uide
S
ervice
ColorPage-Vivid 1200XE USB
figure 2. 9. 5.
Step 5
Notice: To connect the cable to the slot and to prevent
the scanner from losing signal which will
cause the IC burnout on the scanner board ,
please make sure that the connection is
perfect.
How to Replace the Lamp
figure 2.10.1.
Step 1
Disconnect the CCD Connector that is attached to the
CCD Board. Loosen the screw, then you can take off the
Inverter.
Disconnect the Lamp Connector that is attached to
the Inverter.
Notice: Lamps are fragile and could break, please
pay more attention while replacing them.
figure2.10.2.
Step 2
Pull out the Lamp wire gently.
figure 2.10.3.
Step 3
Pull out one end of the Lamp where a protection
rubber is covered, and then the other end.
Front Side