BLIZZARD 400-800 C ENC
21
532104 - Rev.A
1 2
ON
3 4
1 2
ON
3 4
1
RX
TX
-
OPEN B
1 2 3 4 5 6
-
STOP
1 2 3 4 5 6
OPEN B
1 2 3 4 5 6
OUT -
STOP
OUT -
1 2 3 4 5 6
2.5
J6
J6
J6
J6
1
2
3
4
J13
J13
3 9
4 0
Tr
ansla
tion of the orig
inal instruc
tions
ENGLISH
Addressing the
Bus
devices
Position the DIP switches (address) to identify the transmitter-receiver
pair and assign the type of operation (
L
i
The transmitter and receiver of a pair of photocells must have the same
address, but there must never be two or more pairs of photocells with
the same address.
Choose the combinations from the following table:
DIP1
DIP2
DIP3
DIP4
OPERATING MODE
OFF
OFF
OFF
OFF
OPENING (max 5 pairs)
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
CLOSING (max 6 pairs)
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OPENING and CLOSING
(max 2 pairs)
OFF
ON
OFF
ON
ON
ON
ON
ON
OPEN
COMMAND (1 pair)
N.C. CONTACT SAFETY EDGES
The SPRINT M24 board enables
N.C.
contact safety edges to be con-
nected. To do this, one of the inputs,
OPEN B
and/or
STOP
, must be
configured as
SAFE
in Advanced Programming (
Ob
,
SP
).
L
i
It is possible to modify the way the reverse on obstacle function works
in Advanced Programming (
IP
).
A
Fail-Safe
test can be carried out on N.C. contact safety edges via the
OUT
output. If the test fails, the electronic board does not command
the movement.
If there are multiple safety edges, connect the
N.C.
contacts in series.
TYPE
STANDARD MODE OF OPERATION
Closing
contact safety
edges
Active during closing
When an obstacle is detected, they re-
verse the movement until the open posi-
tion is reached. At the second consecutive
obstacle the gate stops(
St
=
02
).
Opening
contact safety
edges
Active during opening
When an obstacle is detected, they
reverse the movement until the closed
position is reached.
INPUT
OPEN B
CONFIGURED AS OPENING SAFETY EDGE
L
i
If logic
b
or
C
are used, it is not permitted to connect the safety edges
to input
OPEN B
.
If logic
A
is used, connect the safety edges after having configured
input
OPEN B
in Advanced Programming
CONNECTIONS
ADVANCED PROGRAMMING
WITHOUT
FAIL-SAFE
TEST
-1
Ob = 01
O1 ≠ 01
WITH
FAIL-SAFE
TEST
-3
Ob = 01
O1 = 01
INPUT
STOP
CONFIGURED AS CLOSING SAFETY EDGE
CONNECTIONS
ADVANCED PROGRAMMING
WITHOUT
FAIL-SAFE
TEST
SP = 01
O1 ≠ 01
WITH
FAIL-SAFE
TEST
SP = 01
O1 = 01