Part No. 133554
Genie TZ-34/20
23
Operator’s Manual
Fourth Edition • Fourth Printing
Pre-operation Inspection
Be sure that the operator's, safety and
responsibilities manuals are complete, legible
and in the storage container located on the
platform.
Be sure that all decals are legible and in place.
See Decals section.
Check for hydraulic oil leaks and proper oil
level. Add oil if needed. See Maintenance
section.
DC models: Check for battery fl uid leaks and
proper fl uid level. Add distilled water if needed.
See Maintenance section.
Check for proper tire pressure and lug
nut torque. Add air to tires if needed. See
Maintenance section.
Check the following components or areas for
damage, improperly installed or missing parts and
unauthorized modifi cations:
Electrical components, wiring and electrical
cables
Hydraulic power unit, reservoir, hoses,
fi ttings, cylinders and manifolds
Boom components and wear pads
Tires and wheels
Trailer lights and refl ectors
Parking brake components
Outriggers and foot pads
Limit switch and alarms
Nuts, bolts and other fasteners
Platform entry mid-rail/gate
Surge brake components
Safety chains (if required)
Light and brake cables
Mechanical brake components (if equipped)
Axle
components
Beacon and alarms (if equipped)
Inspect the Lanyard Anchorage Points.
Be sure the Manual Pump Handle for the
Hydraulic Pump is stowed in place.
Check entire machine for:
Cracks in welds or structural components
Dents or damage to machine
Be sure that all structural and other critical
components are present and all associated
fasteners and pins are in place and properly
tightened.
Be sure that the batteries are in place and
properly connected.
Models equipped with hydraulic surge brake
systems:
Check the hydraulic oil level in the surge brake.
Check for leaks.
After you complete your inspection, be sure
that all compartment covers are in place and
latched.
Inspections