Operator's Manual
Third Edition • First Printing
Inspections
16
Super-Straddle
Part No. 1298031GT
Test Retaining Pin Interlock
7
At the platform controls of the Genie AWP, pull
out the red Emergency Stop button.
8
Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up/down functions should operate.
9
Remove a frame retaining pin from one corner
of the Super-Straddle. The corresponding
interlock display light should be off.
10 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up function should not operate.
11 Insert the frame retaining pin.
12 Repeat this procedure for each frame retaining
pin
Test Outrigger Interlock
13 Pull out the red Emergency Stop button at the
platform controls.
14 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up/down functions should operate.
15 Unscrew one leveling jack until the
corresponding interlock display light turns off.
16 Push in the control activate button and rotate
the up/down switch in the direction of intended
travel.
Result: The up/down function should not
operate.
17 Return the leveling jack to the previous setting
and check the bubble level.
18 Repeat this procedure for each outrigger.
Summary of Contents for Super-Straddle