Second Edition • First Printing
Operator's Manual
Operating
Instructions
Part No. 1261735
S-60X 51
LCD Screen (if equipped)
The LCD screen displays hour
meter, voltage, oil pressure and
coolant temperature. The
screen also displays fault codes
and other service information.
Perkins Engine
Machines equipped with Perkins diesel engines
with an LCD screen have a regeneration mode that
should run automatically when needed.
Left amber light on and high temperature text box
present: Regeneration mode is running. No service
required.
Right side amber light on or flashing: Regeneration
is required.
1
Push in red Emergency Stop button to turn the
machine off.
2
Restart the engine. The regeneration mode
should run automatically.
Left amber light on and no high temperature text
box present: Regeneration mode is turned off. To
turn the regeneration mode on:
1
Push in red Emergency Stop button to turn the
machine off.
2
Restart the engine
Flashing red lights: contact service personnel.
Flashing green lights: contact service personnel
within 24 hours.
Deutz engine
Flashing red lights: contact service personnel.
Flashing green lights: contact service personnel
within 24 hours.