oVeRView of poteNtial haZaRDS

Overhead doors are large, heavy objects that move with the help of springs under high tension and  electric motors .  Since moving objects, springs 
under tension, and electric motors can cause injuries,  your safety and the safety of others depend on you  reading the  information in this manual .  If you 
have questions or do not understand the information  presented,  call The Genie Company .  or your local Genie Distributor . 

POTENTIAL HAZARD

EFFECT

PREVENTION

• Keep people clear of  opening while door is  moving.
• Do Not allow children to play with the door  operator .
• Do Not operate a door that jams or one that has a  broken spring .

MOVING DOOR

WARNING:

Could result in death 

or serious injury .

• Turn off power before removing operator cover.
• When replacing cover, make sure wires are not pinched or near   

                   

  moving parts .
• Operator must be properly grounded.

ELECTRICAL SHOCK

• Do Not try to remove, repair or adjust springs or anything to   

  which door spring parts are  fastened, such as, wood blocks,  

  steel brackets, cables or other like items .
• Repairs and adjustments must be made by a trained door    

  system technician using  proper tools and  instructions .

HIGH SPRING TENSION

WARNING:

Could result in death 

or serious injury .

WARNING:

Could result in death 

or serious injury .

In this section, and those that follow, the words DangerWarning and Caution are used to emphasize important safety   
information .  The word:
 

indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury .

 

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .

 

indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage .

The word NOTE is used to indicate important steps to be followed or important considerations .

DANGER:

CAUTION:

WARNING:

Safe-T-Beam®  (STB) Non-Contact Reversing System 
Places an invisible beam across door opening, that reverses 
the door during down travel to the fully open position if 
anything passes through beam .  

Safe-T-Reverse®  Contact Reversing System 

 

 

Automatically stops and reverses a closing door  within 2 
seconds of contact with an object .

Safe-T-Stop®  Timed Reversed System   

 

 

Automatically opens a closing door, if door does not close 
within 30 seconds .

ForceGuard®  Control   

 

 

 

 

Used to set the force required for opening and closing 
door . For maximum safety, set the minimum force required 
to fully open and close door .

Automatic Lighting System 

 

 

 

 

Light bulbs up to 60 Watts max . , used for safer entries and 
exits . The lights turn on when door is activated and  
automatically turn off 4 .5  minutes later .

Manual Emergency Release 

 

 

 

 

Allows the garage door to be opened or closed manually 
for emergencies or maintenance .

 

 

IMPORTANT  INSTALLATION

INSTRUCTIONS

  1   READ AND FOLLOW ALL SAFETY, INSTALL ATION AND  

      OPERATION  INSTRUCTIONS . If you have any  

 

      questions or do not understand an instruction, call    

      your authorized Genie installation professional .

  2    Do Not install operator on an improperly  balanced    

      door .  An improperly balanced door could cause    

      severe injury .  Repairs and  adjustments to cables,     

      spring  assembly, and  other hardware must be made  

      by a trained service person using proper tools and    

       instructions .

  3   Remove all ropes, and disable all locks connected to  

      the door before installing operator .

  4   Install door operator 7 feet or more above the floor .   

      Mount the emergency release knob 6 feet above    

      the floor .

  5   Do Not connect the operator to the source of power  

      until instructed to do so .

  6    Locate the control button:   

 

 

 

      •  Within sight of door. 

 

 

 

 

      •   At a minimum height of 5 feet, so small  children    

        cannot reach it .   

 

 

 

 

      •   Away from all moving parts of the door.

  7   Install the entrapment WARNING label next to the    

      wall button or console . Install the emergency release  

      tag on, or next to, the emergency release

  8   The operator must reverse when the door  contacts a  

      1-1/2 inch high object on the floor at the  center of    

      the doorway . This is about the size of a 2” x 4” board  

      laid flat .

  t

o

 

ReDuCe

 

the

 

RiSk

 

of

 

SeVeRe

 

iNjuRy

 

oR

 

Death

:

          

  

       

WARNING:

S

afety

 f

eatuReS

Summary of Contents for H8000-07

Page 1: ...F U T U R E R E F E R E N C E Complete with INTELLICODE Remote Control and SERIESII Electronics Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Mode...

Page 2: ...by an authorized dealer Genie will provide all required parts under war ranty at no charge to you but the dealers are independent business people and may render a bench or ser vice call charge for the...

Page 3: ...em Places an invisible beam across door opening that reverses the door during down travel to the fully open position if anything passes through beam Safe T Reverse Contact Reversing System Automatical...

Page 4: ...fore installing Opener C A door opener reinforcement bracket may also be needed to connect garage door to Opener s Door Bracket This Opener is designed for installation on a properly braced sectional...

Page 5: ...overheating conditions Do Not use portable generator This product is designed to operate using standard house current Do Not use alternate power supplies A Check that there is a 15 Amp 120 Volt groun...

Page 6: ...store p GER 2 Emergency Release Kit for entry during power failure store p Wood for header ceiling and or door braces store p Masonry fasteners for Safe T Beam Bracket installation store p Safe T Beam...

Page 7: ...ge door will move slowly the first time it runs until the Opener learns the type of door Ensure the Magnetic Carriage Assembly is engaged and is between the two Limit Switches before operating the Ope...

Page 8: ...utton again Red Learn Indicator Light will go out indicating that memory is stored B Program each additional Remote using step A above up to seven remotes NOTE Each Remote Control must be programmed s...

Page 9: ...re MA 3 Pop off the back of the transmitter Use coin pen screwdriver or any similar device Replace old Battery with new coin type battery Replace back of remote B FOR FLASHLIGHT MODELS Pry open batter...

Page 10: ...the Opener still fails contact a Genie Factory Authorized Dealer for service or call Customer Service at 1 800 35 GENIE NOTE Use ONLY Genie Lubricant GLU 3 Other lubricants may damage the Opener FCC A...

Page 11: ...a rate of 5 cycles per 10 minutes of rest Over cycled Contact Customer Service for further assistance 4 BLINKS Force Settings Check Force Settings NOTE Force Settings are not pre set at factory 1 See...

Page 12: ...circuit and for proper wiring Check Open Force adjustment see Set LimitSwitches and Force Controls on page 7 Adjust as needed Check condition of garage door and door spring s WARNING If you suspect a...

Page 13: ...10 Noisy operation Ensure all fasteners are tightened Check that the garage door and Opener are in good repair properly lubricated and properly balanced See Maintenance page 10 WARNING If you suspect...

Page 14: ...ved Door Arm main carton 1 35 3 8 x 7 8 Hex Head Bolt yellow bag 2 36 3 8 Hex Serrated Flange Nut yellow bag 2 37 2 Conductor Wire main carton 1 Roll 38 Insulated Staple red bag approx 30 40 Wall Cons...

Page 15: ...15 For Help call 1 800 35 GENIE or visit www geniecompany com Hardware Exploded View NOTE Opener will not function unless Safe T Beam System is installed and Force Controls are properly set...

Page 16: ...nge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60 WATT Enhanced Rough Service Light Bulb Ensures proper equipment compatability Bombilla de 60 Vatios...

Reviews: