General Troubleshooting    (Always Check the Status LED Light)

   

Problem 

   

   

What To Do

  Opener does not run  

1 .  Check power source . 

 

 

 

 

 

 

 

  from Remote Control 

  A .  If Opener is connected to an outlet

 

 

 

 

 

 

 

 

   

 

      Plug a working lamp into outlet used for Power Head . 

 

 

 

 

 

   

 

      If lamp glows, power source and outlet are OK .   

 

 

 

 

 

   

 

      If not, check fuse or circuit breaker or non-compatible GFCI . 

 

 

 

 

   

 

    NOTE: A licensed electrician must replace non-compatible GFCI’s.  

 

 

 

   

 

B .  If Opener is connected to a wiring box: 

 

 

 

 

 

 

 

   

 

      Check that fuse is not blown, or circuit breaker is on and not tripped or off .    

 

 

   

 

      If still no power, have a licensed electrician check circuit and wiring . 

 

 

 

   

 

2 .  If Power Source is OK

 

 

 

 

 

 

 

 

   

 

    

 

Check Power Head Terminal connections (Wall Console Installation on Assembly & Installation Poster), tighten if loose . 

 

   

 

    

 

Check

 connections at Wall Console Terminals,  tighten any loose connections .

   

 

Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive  

   

 

Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-35-GENIE .

  Door Opener starts  

      Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires) . 

 

  for no apparent reason 

      Replace any shorting Staples and shorted Wires .  

 

 

 

 

 

   

 

      Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory  

   

 

      and reprogram for remaining remote controls .  (See Erase All Receiver Memory on page 8) .  

 

   

 

      Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls .

  Door starts down, then 

      Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 7) . 

 

  stops before it is  

      Adjust as needed . 

 

 

 

 

 

 

 

  completely closed 

      Check for shorted Wires . 

 

 

 

 

 

 

 

   

 

      Check garage door for binding .

  Door starts down, then 

      If a new installation, check Door Arm position .   

 

 

 

 

 

  stops and goes back up 

      Check operation of Contact Reverse function . 

 

 

 

 

 

 

   

 

      Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses . 

 

 

 

   

 

      Check Safe-T-Beam® System diagnostic code . 

 

 

 

 

 

 

   

 

      Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7) .   Adjust as needed . 

   

 

      Check garage door for binding .

  Door will only run closed 

      Check Open Limit Switch for a short circuit and for proper wiring . 

 

 

 

 

   

 

      Check Open Force  adjustment (see Set Limit Switches and Force Controls on page 7) .  Adjust as needed . 

   

 

      Check condition of garage door and door spring(s) . 

 

 

 

 

 

   

 

      WARNING:  If you suspect a problem with the garage door hardware or springs, contact a Genie  

   

 

      Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE . 

  Door will only run open 

      Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart  

   

 

      (see Safe-T-Beam® System Self-diagnostic Troubleshooting Section on page 13) .    

 

 

   

 

      Check Close Limit Switch for a short circuit and for proper wiring . 

 

 

 

 

   

 

      Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7) .  Adjust as needed . 

  Lights will not go out 

      Disconnect Wires connected to Wall Console .  (Wall Console Installation on 

Assembly & Installation Poster

) .   

   

 

      Check their condition and either replace or reconnect .   

 

 

 

 

 

   

 

      Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls  

   

 

      or Wireless Keypad to operate Opener .                                                                                                                                                                                                                                                                                           

  Door starts up, but stops 

      Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly  

  before it is    

      balanced as detailed in Maintenance Section . 

 

 

 

 

 

 

  completely open 

      WARNING:  If you suspect a problem with the garage door hardware or springs, contact a Genie    

   

 

      Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE .    

 

   

 

      Check Open Limit Switch for a short circuit and for proper wiring . 

 

 

 

 

   

 

      Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7) .  Adjust as needed .

  Operator runs, but door  

       Ensure Magnetic Carriage Assembly is engaged to Rail Drive Screw (see Install Magnetic Carriage Assembly  

  does not move  

      onto Rails on page 10) . 

 

 

 

 

 

 

 

    

 

      Check Force adjustment (see Set Limit Switches and Force Controls on page 7) .  Adjust as needed . 

 

   

 

      Check that all sections of Rail Drive Screw are turning when Motor runs .  If not:    

 

 

   

 

      –    Check condition (not cracked, split, or broken) and placement of Coupler .  Replace as needed . 

 

   

 

      –    Check condition (not cracked, split, or broken) and placement of Collar and Clip .  Replace them                

   

 

           as needed .

  Wall Console Vacation  

      Ensure Magnetic Carriage Assembly is in contact with Close Limit Switch . 

 

 

 

  Lock function does  

      Check when door is fully closed, that Carriage activates Close Limit Switch .  If not, adjust position of Close  

  not work 

 

      Limit Switch (See page 7) . 

 

 

 

 

 

 

 

continued on next page

Summary of Contents for H8000-07

Page 1: ...F U T U R E R E F E R E N C E Complete with INTELLICODE Remote Control and SERIESII Electronics Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Mode...

Page 2: ...by an authorized dealer Genie will provide all required parts under war ranty at no charge to you but the dealers are independent business people and may render a bench or ser vice call charge for the...

Page 3: ...em Places an invisible beam across door opening that reverses the door during down travel to the fully open position if anything passes through beam Safe T Reverse Contact Reversing System Automatical...

Page 4: ...fore installing Opener C A door opener reinforcement bracket may also be needed to connect garage door to Opener s Door Bracket This Opener is designed for installation on a properly braced sectional...

Page 5: ...overheating conditions Do Not use portable generator This product is designed to operate using standard house current Do Not use alternate power supplies A Check that there is a 15 Amp 120 Volt groun...

Page 6: ...store p GER 2 Emergency Release Kit for entry during power failure store p Wood for header ceiling and or door braces store p Masonry fasteners for Safe T Beam Bracket installation store p Safe T Beam...

Page 7: ...ge door will move slowly the first time it runs until the Opener learns the type of door Ensure the Magnetic Carriage Assembly is engaged and is between the two Limit Switches before operating the Ope...

Page 8: ...utton again Red Learn Indicator Light will go out indicating that memory is stored B Program each additional Remote using step A above up to seven remotes NOTE Each Remote Control must be programmed s...

Page 9: ...re MA 3 Pop off the back of the transmitter Use coin pen screwdriver or any similar device Replace old Battery with new coin type battery Replace back of remote B FOR FLASHLIGHT MODELS Pry open batter...

Page 10: ...the Opener still fails contact a Genie Factory Authorized Dealer for service or call Customer Service at 1 800 35 GENIE NOTE Use ONLY Genie Lubricant GLU 3 Other lubricants may damage the Opener FCC A...

Page 11: ...a rate of 5 cycles per 10 minutes of rest Over cycled Contact Customer Service for further assistance 4 BLINKS Force Settings Check Force Settings NOTE Force Settings are not pre set at factory 1 See...

Page 12: ...circuit and for proper wiring Check Open Force adjustment see Set LimitSwitches and Force Controls on page 7 Adjust as needed Check condition of garage door and door spring s WARNING If you suspect a...

Page 13: ...10 Noisy operation Ensure all fasteners are tightened Check that the garage door and Opener are in good repair properly lubricated and properly balanced See Maintenance page 10 WARNING If you suspect...

Page 14: ...ved Door Arm main carton 1 35 3 8 x 7 8 Hex Head Bolt yellow bag 2 36 3 8 Hex Serrated Flange Nut yellow bag 2 37 2 Conductor Wire main carton 1 Roll 38 Insulated Staple red bag approx 30 40 Wall Cons...

Page 15: ...15 For Help call 1 800 35 GENIE or visit www geniecompany com Hardware Exploded View NOTE Opener will not function unless Safe T Beam System is installed and Force Controls are properly set...

Page 16: ...nge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60 WATT Enhanced Rough Service Light Bulb Ensures proper equipment compatability Bombilla de 60 Vatios...

Reviews: