background image

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

12

Opening Cover May Cause Electric Shock

w

iRinG

 d

iaGRam

1

2

3

4

5

6

7

8

9

10 11 12

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17

1

2

3

1

1

2

3

2

3

4

1

2

BLACK

ORANGE

ORANGE

ORANGE

ORANGE

CLOSE

OPEN 

YELLOW

YELLOW

WHITE

WHITE

WHITE

WHITE

WHITE

STRIPED

STRIPED

BLACK

BLACK

PURPLE

GREEN

BLUE

BLUE

RED / WHITE

RED

RED

GREY

GREY

BROW

N

ORANGE

GREEN

GREEN

GREEN

GREEN

OPEN

CLOSE

LIGHTS

WHITE

GREEN

POWER CORD

PRIMARY

SEQUENCER

MOTOR

RPM

SENSOR

WALL 

CONTROL

RADIO CONNECTOR

STB 

SYSTEM

TERMINAL 

STRIP

MOTOR

CAPACITOR

THERMAL 

PROTECTOR

PRIMARY

SECONDARY

TRANSFORMER

SEQUENCER 

HOUSING

(Vcc)

(SIGNAL)

(Vcc)

(TRIP)

(STB SYSTEM

)

(COMMAND)

)

(

1

%

&

/

0

.

+

1

-

$

'

*

3

5

Power Head Assembly

[1]

p

aRtS

 i

dentifiCation

 Item  Part Name
  1  Power Head Assembly 

1

  A  Cover (by Series Model) 

1

  B   Front Plate Assembly 

1

  C  Light Socket 

1

  D  Motor Parts 

2

  E  Receiver Assembly 

1

  F  Capacitor (By Series/Model) 

1

  G  Opto Wheel 

1

  H  Opto-Luctor Assembly 

1

 

J  Sequencer Assembly 

1

  K  Circuit Board Bracket 

  L  Transformer 

1

  M  Terminal Strip 

1

  N  No . 8-32 x 1/2” Hex Head Screw
 

  w/Lockwasher 

1

  P  No . 8-32 x 3/8” Slot Hex Head 
 

  Screw w/Lockwasher 

  R  Capacitor Isolator 

1

  4  1/4-20 Shoulder Bolt 

2

  5  1/4” Flange Nut 

2

  39  Coupler 

1

  41  No . 8-32 x 3/8” Phillips  

 

 

 

  Hex Head Screw 

4

  42  No . 8-32 x 3/8” Phillips 
 

  Pan Head Screw 

2

  48  Mounting Straps 

2

  49  Light Lens 

1

Power Head Parts List 

p

oweR

 h

ead

Number

Included

          

            

WARNING:

Summary of Contents for DirectLift

Page 1: ...up to 7 6 tall Doors Extension Kit available for 8 Doors Included Wall Control MUST be installed prior to Operation of this Garage Door Operator Safe T Beam Safety Reverse System Must be Installed an...

Page 2: ...it yourself repairs Trained service representatives are available Monday Friday 8 00 a m 11 00 p m Eastern Time and on Saturday 10 00 a m to 8 00 p m Eastern Time subject to holidays You may also get...

Page 3: ...em Places an invisible beam across door opening that reverses the door during down travel to the fully open position if anything passes through beam Safe T Reverse Contact Reversing System Automatical...

Page 4: ...olid door including door frame must be braced or reinforced before installing Opener C A door opener reinforcement bracket may also be needed to connect garage door to Opener s Door Bracket This Opene...

Page 5: ...hrough finish material using Lag Screws MOUNTING EXAMPLES Perforated Straps Conduit Perforated Angle Iron Wood Check Ceiling for Grounded Power Source Check Step 6 NOTE Permanent wiring must be instal...

Page 6: ...store p GER 2 Emergency Release Kit for entry during power failure store p Wood for header ceiling and or door braces store p Masonry fasteners for Safe T Beam Bracket installation store p Safe T Bea...

Page 7: ...h Figure MA 2 If door is fully open adjustment is finished If door stops but is not fully open a Measure distance between bottom of door top of door opening b Move OPEN Limit Switch that same distance...

Page 8: ...o delete a Remote Control or Wireless Keypad see To Erase All Receiver Memory C Programming the Remote Controls Programming 1 Accessories To Erase All Remotes from Power Head Memory A Press and hold L...

Page 9: ...igure MA 5 Learn Code Button and Indicator Light 1 Button Compact Remote w Docking Station Figure MA 4 Genie Remote Controls 3 Button Compact Remote w Docking Station A Install two 60 Watt light bulbs...

Page 10: ...ther lubricants may damage the Opener FCC AND IC CERTIFIED All devices comply with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful int...

Page 11: ...tomer Service at 1 800 35 GENIE 5 Check position of Lock Switch on Console Door will only run open 1 Check Safe T Beam System as detailed in the Safe T Beam System Self diagnostic Troubleshooting Char...

Page 12: ...CONDARY TRANSFORMER SEQUENCER HOUSING Vcc SIGNAL Vcc TRIP STB SYSTEM COMMAND 1 0 1 3 5 Power Head Assembly 1 Parts Identification Item Part Name 1 Power Head Assembly 1 A Cover by Series Model 1 B Fro...

Page 13: ...8 Emergency Release Knob 1 19 Emergency Release Tag not shown 1 20 Header Bracket 1 21 Door Bracket 1 22 1 4 x 2 Lag Screw 7 23 Straight Door Arm 1 24 Clevis Pin 2 25 Cotter Pin 2 26 Curved Door Arm 1...

Page 14: ...ulisseau Rallonge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60 WATT Enhanced Rough Service Light Bulb Ensures proper equipment compatability Bombill...