6"

C

HECK

S

AFE

-T-B

EAM

® 

M

OUNTING

B

RACKET

L

OCATION

Check for wood garage frame, jamb, or masonry at mounting location
(6" above floor) with attachment tabs facing away from garage door
(

Figure 7

).

A

If you cannot mount Safe-T-Beam® Mounting Bracket to      
wood frame:

Concrete screws and concrete anchors (not included) 
must be used to mount Brackets on masonry with 
attachment tabs facing away from garage door.

Safe-T-Beam® Mounting Bracket Extensions may be used 
(not included - available from a Genie Factory Authorized 
Dealer or through Accessories Order Form on page 20).

Check Step 7:

R

ECOMMENDED TOOLS

A

Tools (

Figure 8

):

B

Additional tools to make installation easier:

Slotted and phillips screw-driver bits

Stud finder

Sheet-metal cutting snips

Check Step 8:

D

R

EMOVE

E

XISTING

G

ARAGE

D

OOR

L

OCKS

Check that the garage door locks, rope, and T-Handles are removed
from the garage door before starting the installation.

A

If your garage does not have a separate entry door, it is highly 
recommended to install a Genie Emergency Release Kit (

GER-2

).

Emergency Release Kit lets you open garage door from outside if
there is a power failure. (Please see Accessories Order Form on 
page 20.)

Check Step 9:

Before going further, get any items and tools
needed for your installation

Safe-T-Beam® Sensor Mounting Bracket  Extensions (dealer)

Garage door opener reinforcement bracket (dealer)

Garage door frame reinforcement brackets, screws, bracing 
or reinforcement kits (dealer)

Lag Screws (1-1/4") for a wood door less than 2" thick (store)

Electrical outlet and/or wiring (supplied by a                 
licensed electrician)

Sufficient angle iron or strapping for hanging Power Head 
(store)

100 Watt light bulb 
(Rough service bulbs recommended)(store)

GER-2 Emergency Release Kit for entry during power failure 
(store)

Wood for header, ceiling, and/or door bracing reinforcement 
(if needed)

Masonry fasteners for Safe-T-Beam® Bracket installation,
(if needed)

Masonry drill bit (if needed)

Extension Kit (for 8’ Garage Doors)

Source

Sensor

Safe-T-Beam®

Mounting Bracket

Top of

Bracket 6"

above

floor

Figure 7

Mounting Safe-T-Beam® Components

Figure 8

Recommended Tools

6' or 7'

Step Ladder

Electric

Drill

1/16"

Drill Bit

Carpenter's Level

Phillips Screwdriver

Hammer

Adjustable Wrench

Pliers

12' +

Tape Measure

Pencil

Hack Saw

Sockets

Wire

Stripper

Socket

Wrench

3/8"

5/16"

1/4"

7/16" 1/2" 9/16"

5/32"

Drill Bit

Safety Glasses

Summary of Contents for Chainlift 2020

Page 1: ...E R E N C E COMPLETE WITH INTELLICODE REMOTECONTROL AND SERIESII ELECTRONICS Having Difficulty Need Help Please call us 1 800 35 GENIE 354 3643 www geniecompany com Please have Model information ready...

Page 2: ...______ _________ __________ Serial Number ______________________________ Operator Model ______________________________ Remote Control Model ______________________________ Dealer Name _________________...

Page 3: ...Maintenance Brochure DASMA Entrapment Warning Label To be Adhered in close proximity to wall control Assembly and Installation Poster This poster is intended to give a convenient lay flat media to be...

Page 4: ...and auto matically turns off 4 5 minutes later Manual Emergency Release Allows the garage door to be opened or closed manually for emergencies or maintenance IMPORTANT INSTALLATION INSTRUCTIONS 1 REA...

Page 5: ...t bracket if needed before proceeding E If you have a wooden door measure door s thickness 1 4 x 2 Lag Screws are included for installing Door Bracket onto door If your door is less than 2 thick brace...

Page 6: ...rk a point on center line Bottom of Header Bracket will be installed here For one piece doors add 6 to H Mark this point on center line Bottom of Header Bracket will be installed here C Check wall for...

Page 7: ...uit Perforated Angle Iron Figure 6 Mounting methods for open beam or finished ceilings FINISHED CEILINGS Locate ceiling joists or trusses using a stud finder or similar device Attach angle iron not in...

Page 8: ...elease Kit lets you open garage door from outside if there is a power failure Please see Accessories Order Form on page 20 Check Step 9 Before going further get any items and tools needed for your ins...

Page 9: ...ch that same distance toward door If door stops and or reverses before reaching the CLOSE Limit Switch a Slightly increase CLOSE Force setting clockwise If door reverses after contacting floor move Li...

Page 10: ...tion the ladder to the side of the Power Head so it is clear of all moving parts of the Opener and the door Set the door Opener to use the minimum force needed to open the door A Open garage door usin...

Page 11: ...e door will move B Press Button again Garage door will stop The door automatically stops at the end of the open or close cycle C Press Button again Garage door will reverse WARNING A moving garage doo...

Page 12: ...ime If a Remote Control becomes lost or if you want to delete a Remote Control or Wireless Keypad see To Erase All Receiver Memory Transmitter Compliance Statement ABOUTDUAL FREQUENCY REMOTETRANSMITTE...

Page 13: ...use harmful interference and 2 this device must accept any interference received includ ing interference that may cause undesired operation WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1 READ...

Page 14: ...14 For Help call 1 800 35 GENIE or visit www geniecompany com NOTES...

Page 15: ...upted Remove power and reapply 2 BLINKS Pause Beam not aligned Check Source Sensor alignment Repeat ON Beam obstructed Check for obstruction Sensor defective Contact Customer Service 2 BLINKS Pause Wi...

Page 16: ...4 WARNING Ifyoususpectaproblemwiththegaragedoorhardwareorsprings contactaGenie FactoryAuthorizedDealerforservice orcontactCustomerServiceat1 800 35 GENIE 5 Check Position of Lock Switch on Console Doo...

Page 17: ...17 For Help call 1 800 35 GENIE or visit www geniecompany com WIRING DIAGRAM WARNING Shut off power before opening the Cover Components inside Cover May Cause Electric Shock...

Page 18: ...rd Bracket 1 1L Drive Module 1 1M Terminal Strip 1 1N No 8 32 x 3 4 Hex Head Screw w int Lockwasher 1 1P Shock Absorbtion Stop 1 1Q Motor Mount Bracket not shown 1 1X Chassis 1 4 1 4 20 Shoulder Bolt...

Page 19: ...26 Curved Door Arm main box 1 27 3 8 16 x 7 8 H H Bolt yellow bag 2 28 3 8 16 Hex Flange Nut yellow bag 2 29 Wire main box 1 30 Insulated Staples red bag varies by model Parts List Item Part Name 31 W...

Page 20: ...ain Glide para acomodar unapuertade8 pies 2 43 m N cessaire de prolongement du coulisseau Rallonge de prolongeant la course de l ouvre porte Chain Glide pour une porte de 2 4 m 8 pi de hauteur 60WATT...

Reviews: