6
TRAVEL LIMITS
NOTE:
If shuttle/bullet has
NOT
been engaged to carriage, do so now.
See page 17.
NOTE:
You have
30 seconds
to execute each step. If you see
two
solid red or flashing LEDs on the Powerhead
, you have run out of
time and must go back to the beginning of the step and start over. You
can restart as many times as necessary to complete each step.
Closing Garage Door (Down Limits)
(continued next page)
s-AKESUREDOORWAYISINVIEWANDCLEAROFOBSTACLESAND
people to avoid injury or damage to property.
s
DO NOT
operate this unit from wall console before
LIMITS
are set. Severe damage to the opener can occur.
s4HESHUTTLE
MUST
be engaged to carriage
BEFORE
setting limits.
See
Installation Poster
(if provided) or call Customer Service at
1-800-35GENIE or visit
www.geniecompany.com
WA R N I N G
1
1
2
1
Lift the door open by hand until the shuttle/bullet
engages the carriage on the rail.
PROGRAM
SET
–
+
3
Release
down arrow button (-)
and the long LED
will begin flashing.
PROGRAM
SET
–
+
PROGRAM
SET
–
+
HOLD
4
Press and hold the
down arrow button (-)
until
garage door is fully closed, then release.
PROGRAM
SET
PROGRAM
SET
–
+
HOLD
2 seconds
HOLD
2 seconds
2
Press and hold the
down arrow button (-)
for
2 seconds until the long LED comes on blue
(round LED remains off).
Required Programming
3