24
PoE input (PoE In) Pinout
Daisy-chain PoE Line1, PoE Line2
Provides Daisy-chain connection function to supply data and power from PoE to another PoE Line.
PoE Line1 and PoE Line2 provide the ability to use the input power from the PoE and supply the remaining
power to the other PoE Line. Make sure that you use only those network switches that follow the standard PoE
specification when connecting the network switch to the Daisy-chain PoE Lines.
!!! Note:
Without the use of standard PoE specification network switches,
devices connected to the Daisy-
chain PoE Line can be severely damaged.
Connect the network switch to the PoE In port.
!!! Note:
Do not connect the Daisy-Chain PoE Lines to the PoE port on
the BSCCK550 cascade kit (for
BS750, BS550, BS250)
.
Power-on Sequence
⚫
Power on the network switch
directly connected to the GENIE Base Station first, and then power on the
GENIE devices.
⚫
For use in conjunction with a GENIE Panel, only the GENIE Base Station shall be set to Master. If Panels are
used only, set one Panel to Master. Always power on the device that is set to Master first.
⚫
If the Multi-Sync cable between Base Stations is connected, the Master Base Station must be powered on
first. Otherwise, the Slave Base Station will not operate normally.
Verify and Monitor with GCM program after Installation
⚫
Check out the LAN connection status of the devices.
⚫
Identify for the most ideal frequency settings for wireless devices such as BS1000, BS850, RA100DW, RA100,
and RBS85 which are installed in an Antenna coverage zone.
⚫
When setting frequencies, it is recommended that you maintain at least two frequency band intervals relative
to the frequencies of other radio devices.
⚫
When installing, deploy GENIE wireless devices at a location further than 10 meters away from other wireless
devices such as WiFi AP or Mobile phone Repeater.
Other Recommendations
⚫
Use the key lock function on Beltpack to prevent it from abnormal operation.
⚫
When connecting external equipment such as Matrix by using a 4Wire Line of GENIE Base Station, make
sure you perform the ground connection or ground cut to avoid any possible ground noise.
⚫
Install the Ethercon connector on the LAN cable.
⚫
For RA100DW, you must use an RJ45 connector for IP67 waterproofing, included with the product box.
Antenna installation
BS1000/BS850/RA100DW/RA100/RBS85 must be used after its antenna connection
. If the antenna is
not connected and operated, then
RF related circuits
may be
damaged.
Frequency Setting Recommendations
In case of those sites where there are severe RF interferences with multiple Wi-Fi installations, it is recommended
to use the radio bands as below, which are not used by Wi-Fi. Check if the radio band is available in your local
area before using it.
LaON ID Number.
WI-FI Channel
Frequency
Band
1
32
5160 MHz
5150~5170 MHz
10
68
5340 MHz
5330~5350 MHz
11
96
5480 MHz
5470~5490 MHz
28
169
5845 MHz
5835~5855 MHz
29
173
5865 MHz
5855~5875 MHz
Pin
Mode B
Mode A
Power
Wire Color
Data
Power
Data
Power
1
White
/
Orange
TxRx A +
TxRx A + DC +
+PWR
2
Orange
TxRx A −
TxRx A − DC +
+PWR
3
White
/
Green
TxRx B +
TxRx B + DC −
-PWR
4
Blue
TxRx C +
DC +
TxRx C +
+PWR
5
White
/
Blue
TxRx C −
DC +
TxRx C −
+PWR
6
Green
TxRx B −
TxRx B − DC −
-PWR
7
White
/
Brown
TxRx D +
DC −
TxRx D +
-PWR
8
Brown
TxRx D −
DC −
TxRx D −
-PWR
Pin
Mode B
Mode A
Power
Wire Color
Data
Power
Data
Power
1
White
/
Orange
Rx +
Rx +
DC +
+PWR
2
Orange
Rx −
Rx −
DC +
+PWR
3
White
/
Green
Tx +
Tx +
DC −
-PWR
4
Blue
DC +
Unused
+PWR
5
White
/
Blue
DC +
Unused
+PWR
6
Green
Tx −
Tx −
DC −
-PWR
7
White
/
Brown
DC −
Unused
-PWR
8
Brown
DC −