GeneSys Elektronik GmbH
In der Spöck 10
77656 Offenburg
Germany +49 (0) 781 96 92 79
–
0 [email protected] www.genesys-offenburg.de
ADMA 3.5 Quick Start Guide.docx
Seite / Page 27 / 32
9
KEY VALUES IN MEASUREMENT MODE
9.1
SYSTEM STATUS
Channel Name
Description
Status_Standstill
Standstill detection
1 = vehicle standstill detected
0 = vehicle movement detected
If vehicle standstill is not detected,
accordingly adjust the system parameters
(see User Manual).
Status_Count
Status variable count
Increases by one for each transferred data
record. Reset to 0 after 255 transfers. This
value indicates potential low voltage or data
recording problems.
Error_Hardware
Fault messages
It is not worth continuing with a
measurement if a hardware error occurs.
Warn_GNSS
Warn_Misc1
Warning messages
Depending on the measurement task,
warning messages can be ignored or must be
analysed individually (see Technical
Documentation).
Status_Kalmanfilter_settled
Kalman filter status
1 = Kalman filter settled in all axes.
0 = Kalman filter not complete initialized.