GeneSys Elektronik GmbH
In der Spöck 10
77656 Offenburg
Germany +49 (0) 781 96 92 79
–
0 [email protected] www.genesys-offenburg.de
ADMA 3.5 Quick Start Guide.docx
Seite / Page 11 / 32
3.3
STATUS OPERATING MODE ADMA-SPEED
Port
LED
Description
9-32 V DC IN
⚫
⚫
OFF
OFF
No supply voltage
9-32 V DC IN
⚫
⚫
ON
OFF
Supply voltage connected
ADMA boot process started
9-32 V DC IN
⚫
⚫
ON
ON
Ready for operation
State
⚫
ON
Ready for operation
Modem
⚫
ON
Modem port activated
CAN1
⚫
Data output via CAN
Ethernet1-3
⚫
⚫
Data
Link
IMU
⚫
ON
IMU connected
Signal
⚫
ON
+ 5V DC and +12V DC power at signal out port active