7
RECOMMENDED SETTINGS
BEHAVIOUR
Autostart
The ADMA will start the measurement-
mode automatically after powering up.
Prealignment
The horizon is determined during this
period. Do not move the vehicle, do not
close doors.
Typical values:
10 sec for passenger cars
20 sec for trucks
DATA LINK
Interface Selection
Used interfaces for data output.
Interface CAN:
Define the CAN interface hardware
settings.
The default
Base ID
is set to 100 dec.
The
CAN baud rate
is usually set to
1000 kBaud. This provides the following
advantages:
•
Greater number of maximum
channels
•
Higher data rate
•
Lower transmission time
Ethernet Settings
The IP settings of each Ethernet interface
can be done manually.
In case the connection to the user defined
IP address fails use the default IP
192.168.88.30.